VEVOR Pool Heat Pump Max 93390 BTU, Electric Pool Heater for Above & In-Ground Up to 22455 Gallons, All-DC Inverter Technology, WiFi & App Remote Control, Multiple Protection for Swimming Parties

VEVOR Pool Heat Pump Max 93390 BTU, Electric Pool Heater for Above & In-Ground Up to 22455 Gallons, All-DC Inverter Technology, WiFi & App Remote Control, Multiple Protection for Swimming Parties

17.23~85.58kBtu/h
Questions and Answers
7 Questions
I have VBPYCA-250. I direct wires with 8ga from panel to unit. Should the breaker be a GFCi breaker ?
Yes, a GFCI breaker is required.
By vevor
What is the optimal compressor pressure (the guage on the side of the heat pump). Is it around 2?
The optimal pressure value depends on the current ambient and water temperatures. Under normal conditions, the appropriate pressure range (as indicated by the high-pressure gauge) is 1.6–2.6 MPa; however, under extreme operating conditions, the pressure may exceed 3 MPa. If this response does not resolve your issue, please contact us again for assistance.
By vevor
I have a 1.5 hp pump/filter. I have a bypass installed before the heat pump. How do I gage how much to by pass? Its 76-80 ambient, 76 inlet water, heating to 85, what should the outlet water temp be to be most efficient?
Water flow is optimal when the difference between the inlet and outlet water temperatures is 4°F (2°C). It is recommended to set the target temperature to 83°F. If this answer does not resolve your issue, please contact us again for assistance.
By vevor
I believe the linkage switch would allow me to connect pool lights and control switching then on and off with the app. Is this correct? Are there any instructions for use? I see very little in the manual regarding this feature
To set this up, wire your lights or auxiliary equipment to the dedicated linkage/relay terminal ports on the heat pump's main PCB, then configure the linkage mode within the mobile app's settings menu to enable remote switching. Because this process involves low/line voltage connections on the control board, we recommend consulting a qualified electrician to ensure proper wiring according to local electrical codes.
By vevor
Thank you for contacting VEVOR support regarding our Max 93,390 BTU Electric Pool Heat Pump. Yes, that is correct; the linkage switch feature allows you to connect external equipment—such as pool lights or an auxiliary water pump—and synchronize or control their power state directly via the heat pump’s control board and companion smart app
By vevor
The heat output must vary with the outside air temperatures. How low an outside temperature will it work in? i.e. what is the low temp shut off point? At 50, 60, 70 F, what will the BTU output be at these temps?
The unit can operate at a minimum ambient temperature of -7℃, which is approximately 19°F; this is the lowest outdoor temperature at which it will function—there is no explicit “low temp shut-off point” stated, but operation ceases below -7℃.
By vevor