VEVOR 3 Phase Converter - 15HP 53A 220V Single Phase to 3 Phase Converter, 220V Input/Output, Digital Phase Shifter for Residential & Light Commercial Use (One Converter for One Motor Only)
15 HP
Questions and Answers
13 Questions
I see this unit is rated for 220-240v. My supply voltage runs a little hot at 245. Is this out of range for what this unit can handle?
The product is 220 volts, and 245 volts can be used without problems. However, your current inverter can only be used for three-phase asynchronous motors, and cannot be used for any equipment other than three-phase asynchronous motors.
By vevor
This can be used as a power supply to power a cnc milling machine. Not just to run a motor, correct?
Can I connect this converter to the VFD for variable speed control or does it go directly to the motor only?
Can't say for sure. Used it to run a 5 HP 3 Phase 220 Volt motor using Single Phase 220 Volts power input to the Converter and 220 Volt 3 Phase output power 120 Volts on each leg
By Augustine Bryce
Will this operate my 10 HP 3600 RPM diesel pump that draws 24 amps
Yes, this can work for your device. Our 10HP model is enough for your 10 HP 3600 RPM diesel pump drawing 24 amps, and the 15HP model would be too large. Importantly, your motor must be a three-phase 220V asynchronous motor.
By vevor
I havd a three phase compressor 48 amp will this converter work
However, you should also verify that:
Your compressor is 220–240 V, 3-phase.
The motor power does not exceed 15 HP.
The compressor's startup current does not exceed the converter's capabilities.
If this response does not resolve your current issue, please contact us again for assistance.
By vevor
Based on the information provided, yes, it is likely compatible, provided your compressor meets the converter's other requirements.
Your compressor draws 48 A (3-phase).
This VEVOR phase converter is rated for 15 HP with a maximum output current of 53 A.
Since 48 A is below the 53 A maximum, it is within the converter's current rating.
By vevor