VEVOR Heat Exchanger 3\"x7.5\" 40 Plates Brazed Plate Heat Exchanger 316L 3/4\" MPT Heat Exchanger B3-12A Beer Wort Chiller for Hydronic Heating

VEVOR Heat Exchanger 3\"x7.5\" 40 Plates Brazed Plate Heat Exchanger 316L 3/4\" MPT Heat Exchanger B3-12A Beer Wort Chiller for Hydronic Heating

40 pcs
Questions and Answers
23 Questions
The description says "preset temp" , is this capable of regulating temp?
Yes, for example, the cold water side needs to increase the temperature through partition heat exchange. It has an inlet water temperature and an outlet water temperature. The outlet water temperature is the preset temperature that the customer wants, but whether it can be achieved depends on the specific working conditions. . Heat exchange = temperature difference * flow * specific heat * specific gravity.
By vevor
Are your heat exchangers lead free for use with potable water in a residential radiant floor system
Our product does not contain lead. For drinking water, this is a copper brazed plate heat exchanger. The main body is stainless steel, and the solder is 99.9% pure copper. Copper is a heavy metal. If the customer has high requirements for water quality, it is not recommended to use it. However, many customers also use this product for food. Although copper is a heavy metal, it is stable when the temperature is not too high. It is generally recommended that the temperature should not exceed 100°C
By vevor
What is the mass flow rate range of this product?
The maximum flow rate of this model is 8m³/h (8000L/h), and the minimum is about (700L/h). The main thing is that the medium inside must form a steady flow, so that the effect is good. It is recommended that you add a regulating valve to the inlet pipeline to adjust the flow rate, because the flow rate also needs to consider what the medium is. Different media have different viscosities and heat transfer coefficients.
By vevor
What is the thread size
The thread of this model is external thread NPT3/4.
By vevor
Hello, What filter size should I use to prevent blocking the inside of heat exchanger?
Hello, it is generally recommended to use a filter of 60 mesh or above.
By vevor