Questions and Answers
52 Questions
Do you have an on-line PDF Manual for this VEVOR VFD 7.5KW 220V 10HP, 1 or 3 Phase Input, 3Phase Output which I may download ?
Here is the link to the manual: https://d2v0huudrf11kh.cloudfront.net/vevor-center-goods/H100manualV1.8%EF%BC%88%E6%96%B0%E5%91%BD%E5%90%8Dls%EF%BC%89%281%29%281%29_1653643589767.pdf.
By vevor
Vevor model at1-7500x on a 80 gallon air compressor. How to wire the two wires from the pressure switch and program. No F001 option 1 on this VFD. Looks like I need To hook to a 24v out and signal back. When the air reaches the max it opens the contact on the pressure switch. I was thinking it was DI1 and com is what I need but need to find the parameter to make it shut off when contact is broken. Wiring contacts on pressure switch now are normally closed until pressure is met opening thecontact
Please connect the two wires of the pressure switch to the X1 and GND terminals, and set parameter F000 to 0 and F001 to 1.
By vevor
What size VFD do i need to run a 5hp 3 phase 13.4a 220v motor with a single phase 240 volt 60hz feed? I am looking at your at your 7.5 KW 220v 10hp 1or 3phase input VFD.
This VFD can be powered by single-phase 220V and can be applied to 50 or 60Hz power supply. The output of the VFD is three-phase 220V, so it can drive the motor you mentioned. The power supply wire is connected to the L1 and L2 terminals, and the motor wire is connected to the U, V, and W terminals.
By vevor
I have a Bridgeport Milling Machine with the 3 phase 1HP motor. Can the VEVOR VFD 7.5 KW be used to power this motor properly ?
Yes, as long as the motor is powered by three-phase 220V.
By vevor
This unit also comes preset for operating a 50Hz motor. The instructions in the User Instructions do not tell how to change this. Here's how. F005 - max frequency - must first be set to 60 before changing F003 or F004. Then it is possible to change F004 and F003 to 60 or less. F003 is called main frequency - it is the freq pulled when not using the pot. F004 is the Reference frequency - not clear what role this serves. F005, max freq, must be set first to change 03 or 04
If your motor is 60Hz, you need to set parameter F005 to 60, then set parameter F004 to 60, and finally set parameter F003 to 60.
By vevor