Questions and Answers
12 Questions
What is the output power with single phase 220 input?
The maximum motor power it allows is 7.5 kW. The input power varies with the load of the motor, the maximum power may reach 11 kilowatts, and the limit current may reach 15 kilowatts. The input power is not constant, but depends on the load of your motor, and then the inverter will input and output accordingly.
By vevor
How long till this is back in stock
The product is expected to be available within three months. It is recommended that you add it to your wish list and you will be automatically reminded when the product arrives.
By vevor
What is the best way to keep dust out of the VFD inverter? A mesh bag? Build an enclosure? It will be located in my wood shop.
It is recommended that you use a relatively large box and pay attention to heat dissipation. That is to say, the inverter is placed inside the box, but there needs to be air circulation to lower the temperature of the box. It is best to use a larger iron box, so that the iron box can naturally dissipate heat. If there is ventilation, it is best to add a sponge to the air inlet to keep the dust out.
By vevor
I want to use your VFD inverter to convert single phase to 3 phase to drive my 5 HP 3 phase SawStop. 8s this feasible?
Yes, as long as your motor can be changed to three-phase 220 volts.
By vevor
Is there a way to return all settings to default?
Yes, pn32 is the parameter to restore to factory values. power connection method, If you use single-phase 220v, please connect it to R and T. If S is empty, there is no need to connect it. If you have 3 phase 220v then connect to RST. The three wires of the motor are connected to U, V, and W. Only wires can be connected between the motor and the inverter, and no switch can be installed in between.