Questions and Answers
4 Questions
This looks like what I need to power my 3 phase dust collector.  Its 2 HP and draws 6 amps when on 3 phase.  I need to convert my single phase power.  other question is what is the switch you show it hooked up to?
It is suitable. You need to ensure that the motor must be three-phase 220v. That is, the voltage of your motor must be 220 volts. You cannot add a switch between the inverter and the motor. You need to use an external port to control  the startting and stopping of the motor. The external start application method is as follows: pn04=2 pn07=2 The hardware connection is described as follows: FWD and GND connect forward, disconnect to stop REV and GND connected to reverse transmission, disconnected to stop FWD and REV are connected to GND at the same time, reverse transmission, all disconnected stop
By vevor
I need to power an ice machine compressor. The electrical requirements are 208-230/60/3 (Volts/Hz/Phase), 15 (max fuse size or HACR circuit breaker), 2 (compressor horsepowe)r, 3 (circuit wires), 5.8 (minimum circuit ampacity). Which product do you recommend to go from single phase to the listed electrical output?
Please see the file for reference, the link is valid in 3 days: https://we.tl/t-Dna9D7BFRs.
By vevor
Can I install the inverter ahead of the start/reversing switch at the machine ,with a switch at the inverter to power it up at the power supply ? I would be using it to supply 6o cycle to a mill or lathes one at a time .
No, a switch cannot be installed between the inverter and the motor. But you can lead your switch signal to the control terminal of the frequency converter, which is the forward and reverse signal, and input it into the frequency converter. The frequency converter will allow your motor to realize forward and reverse rotation. Because the output of the frequency converter can only power the machine, not any other power supply on your equipment.
By vevor
i purchased the a2-8030 for a 2 HP 240 volt three phase small lathe I have had for years. Hooked it directly to motor. as soon a the VFD is turned on the fault OC-r, which says overload or component fail. With motor disconected (NO load) the VFD is showing 260 volts between all three legs. motor plates states 6.4 amps full load. what can I do to get it to run?
This is caused by a switch between the inverter and the motor. The simplest description is that you are using the inverter as a power supply, which is not allowed. Just connect the switch on your equipment to start and stop, and the frequency converter will control it.
By vevor