Unlock the full potential of your VEVOR Weather Station Indoor Outdoor with our comprehensive product manual download. Designed with user-friendliness, this manual ensures that setting up, troubleshooting, and optimizing your 7.5-inch Large Color Display Wireless Digital Home Weather Station is a breeze.
Whether you’re configuring the sensor atomic clock, adjusting the backlight, or deciphering forecast data, our detailed guide provides step-by-step instructions and valuable insights. This all-in-one manual also covers calendar and alarm alerts, ensuring you get the most accurate temperature readings and weather predictions.
Download today and take control of your home weather monitoring confidently and easily.
MODEL: YT6077

This is the original instruction. Please read all manual instructions carefully before operating. VEVOR reserves the right to interpret our user manual. The appearance of the product shall be subject to the product you received. Please forgive us for not informing you again if there are any technology or software updates on our product.
WEATHER STATION UNIT


- Outdoor temperature/humidity reading
- Atmosphere display
- Indoor temperature/humidity reading
- Moon phase display
- Time display
- Weekday display and Calendar with month and date display
- Battery compartment (3 x AAA batteries)
- TIME SET button
- ALARM button
- ALERT button
- ▲/MAX/MIN button
- SNOOZE/DIMMER button
- ▼/RCC/°C/°F button
- HEAT/DEW button
- CHANNEL button
MAIN FEATURES
- Colorful and big digit display with super bright backlight.
- 8 functional buttons: TIME SET, ALARM, ALERT,▲/MAX/MIN, SNOOZE/DIMMER, ▼/RCC/°C/°F, HEAT/DEW, CHANNEL.
- Self-setting accurate atomic time function.
- Time display: Hour, minute.
- Calendar display: Month, date, and weekday.
- 9 time zones: EST, NST, AST, HST, AKT, PST, MST, CST, EST.
- Alarm with snooze function.
- Display Indoor & outdoor temperature (°C/°F) &humidityreadingswith trend.
- Low battery indication for both the weather station and wireless sensor.
- 3-level brightness of backlight.
OUTDOOR TEMPERATURE & HUMIDITY SENSOR STATION
1. MAIN FEATURES
- Temperature & Humidity measurement.
- Low Battery Indication.
2. TX BUTTONS ON THE BACK
- LED: Flashes when the unit transmits a reading
- Wall mount
- Channel switch: Channel 1,2,3 inside battery compartment
- Temperature unit switch: ℃/℉, inside battery compartment
- Battery compartment: Use 2 x AAA batteries
- Battery door

FIRST TIME TO USE
1. PAIR THE OUTDOOR REMOTE SENSOR
First, the outdoor sensor and the weather station need to pair. Please follow the procedure below to pair the sensor.
1) Plug the included AC-AC adaptor into the weather station. (optional) Insert 3 new “AAA” alkaline batteries for backup. The screen is turned on. It starts to search the sensor and registers the received sensor. During RF pairing, the signal strength icon will animate until the sensor signal is received or for 5 minutes if no signal is available.

Note: If no sensors are paired, you can pair the sensor again manually by pressing and holding the (CHANNEL) key for over 2 seconds. Please refer to “SEARCH FOR OUTDOOR SENSOR”.
2) Insert 2 new“AAA” alkaline batteries for the wireless outdoor remote sensor.
3) The wireless remote sensor will transmit the signal, and the LED will flash during transmission.
4) Keep the outdoor sensor 5-10 feet from the weather station.
5) When the RF connection is established, the station’s temperature and humidity readings will appear.

6) After the RF connection is established or 5 minutes of pairing time, the weather station will automatically receive the atomic clock signal, and the RCC receiving dot icon will flash.

7) The signal strength indication will be indicated when the weather station detects the atomic clock signal.

8) Protect the weather station from interference from electronic devices. (TV, computer, microwave, radio, etc.)
9) The time and date will be updated when the atomic clock signal is received successfully.

10) Allow the outdoor sensor and weather station to sit together for 15 minutes to establish a strong connection.
11) Do not press any button for 15 minutes.
12) After 15 minutes, place the sensor in a shaded outdoor location.
ATOMIC CLOCK RECEPTION
- The weather station automatically begins searching the WWVB signal and updating the time every day at 1:00 a.m., 2:00 a.m., 3:00 a.m., 4:00 a.m., and 5:00 a.m.
- The Atomic Time tower icon will flash while searching and be solid when connected.
1. MANUAL RCC RECEPTION
You can receive the atomic clock signal manually. In the Normal display, press and hold 【▼/RCC/°C/°F】over 2 seconds to receive the atomic clock signal manually. The RCC receiving dot icon will flash and start atomic clock reception. When the atomic clock signal is received successfully, the time and date will be updated.

During atomic clock reception, press and release the (▼/RCC/°C/°F) button to exit atomic clock reception.
For information about WWVB, visit www.nist.gov/pml/div688/grp40/wwvb.cfm
TIME SETTING
In Normal time display, press and hold the【TIME SET】over 2 seconds to enter time setting mode.
Press and release the【▲/MAX/MIN】and 【▼/RCC/°C/°F】to adjust the values. Hold to adjust quickly.
Press and release 【TIME SET】to confirm and move to the next item.
1. SETTING ORDER
1. RCC On/Off
2. DST On/Off
3. TimeZone
4. Year
5. Month
6. Date
7. 12/24 Hour Format
8. Hour
9. Minute
10. End of Setting
1.) Press and hold the 【TIME SET 】button to access the settings. RCC ON flashes. Press 【 ▲/MAX/MIN 】and 【▼/RCC/°C/°F】to set RCC on/off. Press 【TIME SET】to select DST on/off. Note: If RCC OFF is selected, you will skip DST settings and move year setting.
2.) When DST ON flashes, press the 【▲/MAX/MIN】or the 【 ▼/RCC/°C/°F 】button to select DST on/off. Press 【TIMESET】to select Time Zone.
3.) When the Time zone flashes, press 【▲/MAX/MIN】or【 ▼/RCC/°C/°F】to adjust the time zone(EST, NST, AST, HST, AKT,PST,MST, CST, EST). Press 【TIME SET】to select the Year.
4.) When Year flashes, press 【▲/MAX/MIN】or【 ▼/RCC/°C/°F】to adjust the year. Press 【TIMESET】to select Month.
5.) When Month flashes, press 【▲/MAX/MIN】or【 ▼/RCC/°C/°F】to adjust the month. Press【TIMESET】to select date.
6.) When Date flashes, press 【▲/MAX/MIN】or【 ▼/RCC/°C/°F】to adjust the date. Press 【TIMESET】toselect 12/24-hour time format.
7.) When 12 Hr flashes, press 【▲/MAX/MIN】or【 ▼/RCC/°C/°F】to adjust 12-hour or 24-hour time format. Press【TIME SET】to select the hour.
8.) When Hour flashes, press 【▲/MAX/MIN】or【 ▼/RCC/°C/°F】to adjust the hours. Press 【TIMESET】to select minute.
9.) When Minute flashes, press 【▲/MAX/MIN】or【 ▼/RCC/°C/°F】to adjust the minutes. Press 【TIMESET】tosaveallsettings and exit the settings.
Note: If there is no valid operation within 20 seconds, it will automatically return to the normal display mode from the setting mode.

SET ALARM TIME
1. CHECK ALARM TIME
In Normal time display, press 【ALARM】to switch display alarm time (Alarm time mode).

2. SETTING THE DAILY ALARMS
In Alarm time display, press and release 【ALARM】toconfirmandmove to the next item.
- Press and hold 【ALARM】over 2 seconds to enter alarm setting mode. The Hour of Alarm starts to flash.

- Press 【▲/MAX/MIN】or 【▼/RCC/°C/°F】button to set required alarm hours. Hold the 【▲/MAX/MIN】or the 【▼/RCC/°C/°F】button to adjust alarm hours quickly. Press 【ALARM】toselectminute of Alarm.
- The minute section of the Alarm flashes.

- Press 【▲/MAX/MIN】or 【▼/RCC/°C/°F】button to set required alarm minutes. Hold ▲/MAX/MIN】or 【▼/RCC/°C/°F】button to adjust alarm minutes quickly.
- Press 【ALARM】to save all settings and exit to alarm mode. Note: If there is no valid operation within 20 seconds, it will automatically return to the normal display mode from the setting mode.
3. DEACTIVATE/ACTIVATE ALARM
- In Alarm time display, press 【ALARM】to select the alarm on or off.
- If the alarm is on, its corresponding icon will appear on the display.

4. SWITCHING OFF THE ALARM SIGNAL
- When the alarm is ringing, press any buttons except【Snooze/Dimmer】to stop the alarm signal. It is not necessary to activate the alarm. It will ring again this time next day.
5. SNOOZE FUNCTION
- When the alarm rings, press 【Snooze/Dimmer】buttontopausethe alarm. The snooze indicator icon keeps flashing.
- The alarm will resume after 5 minutes.
HEAT INDEX AND DEWPOINT
- The value of HEAT INDEX is displayed when the outdoor temperature is≥80°F. The value of DEW POINT is displayed when the outdoor temperature is < 80°F.
- Press 【HEAT/DEW】to switch between the heat index and dewpoint displays. Humidity is not displayed when the heat/dewpoint index is viewed.

TEMPERATURE AND HUMIDITY TREND
1. TEMPERATURE TREND
The temperature trend indicators update every 15 minutes and look back over the past hour.
- Change in temperature (2°F/1°C)

2. HUMIDITY TREND
The humidity trend indicators update every 15 minutes and look back over the past hour.
- Change in humidity (3% RH)

3. TEMPERATURE AND HUMIDITY MAX/MIN RECORD
Press 【 ▲/MAX/MIN】 to display the maximum indoor/outdoor temperature and humidity value, press again to display the minimum value, and press again to return to the normal display.
Note: If there is no valid operation within 5 seconds, it will automatically return to the normal display mode from the setting mode.
4. HUMIDITY COMFORT INDICATOR
- The number of grids displayed corresponds to the humidity range.

ALERT FUNCTION
- In normal display mode, press 【ALARM】to turn on/off the alert function. When the alert function turns on, the icon will display.
Note: The Alert function is turned off by default when powering up.
1. CHECK ALERT VALUE
- In normal time display, press 【ALERT】to displaythehighalertvalue of indoor and outdoor temperature and humidity. The icon will display. Press 【ALERT】 to display the low alert value of indoor and outdoor temperature and humidity. The icon will display.
- Press 【ALERT】 to return to normal display mode.
2. SETTING THE ALERT
- In normal time display, press and hold 【ALERT】over 2secondsto enter alert setting mode.
- Press and release 【 ▲/MAX/MIN 】or 【▼/RCC/°C/°F】toadjust the values. Hold to adjust quickly.
- Press and release 【ALERT】to confirm and move to the next item. The icon will display when the upper limit value is set, and the icon will display when the lower limit value is set. The setting item flashes.
3. SETTING ORDER
- Outdoor temperature upper limit value
- Outdoor temperature lower limit value
- Outdoor humidity upper limit value
- Outdoor humidity lower limit value
- Indoor temperature upper limit value
- Indoor temperature lower limit value
- Indoor humidity upper limit value
- Indoor humidity lower limit value
- End of setting
Note: When setting the alert value, press 【CHANNEL】to switch to set for other outdoor temperature/humidity sensors.
4. ALARM
- When the temperature or humidity alert is activated, the corresponding value and alert icon flash. The alarm is automatically turned off after 1 minute of continuous ringing, but the alert icon will still flash.
- If the alarm is not for the currently displayed outdoor sensor, only the alert icon will flash and the alarm will ring, but the alert value will not be displayed.
5. DEACTIVATE THE ALARM
- When the alarm is ringing, press any buttons to stop the alarm. The alert indicator icon keeps flashing.
- Temperature or humidity returns to the alert value range to automatically stop the alarm.
SWITCH READING DISPLAY FOR THE OUTDOOR TEMPERATURE/HUMIDITY SENSORS
- In Normal display, press and release 【CHANNEL】tointerchangethe the reading display for the outdoor temperature/humidity sensors.
- There are CH1, CH2, CH3, or cycle display.
- In cycle display mode, the outdoor temperature reading will be switched every 3 seconds.
COMFORT INDICATION
- There are 3 stages of indication: Dry, Comfort, and Wet.

WEATHER FORECASTING FUNCTION
- The weather symbols indicate the weather fluctuation over the next 6- 12 hours, not the current weather.
- Please consider the weather forecast from your local weather forecasting service and the forecast from your weather station. If there are discrepancies between the information from your device and that from the local weather forecasting service, please consider the latter as authoritative.
- The weather forecast is calculated by evaluating fluctuations in the barometric pressure and may deviate from the actual weather conditions.
- The weather station displays the following weather symbols:

SEARCH FOR OUTDOOR SENSOR
- In Normal time display, press and hold 【CHANNEL】over 2 seconds to search the outdoor temperature and humidity sensor.
- The signal strength icon will animate until the sensor signal is received, or if no signal is available for 5 minutes, it will solidly display.
![]()
SWITCH TEMPERATURE UNIT
In Normal time display, press and release 【 CHANNEL】 to interchange CHANNEL】tointerchangethe temperature unit between degrees Celsius and Fahrenheit.
BACKLIGHT
- When operating with the power cable, there are 3 levels of brightness for adjustment.
- Press 【SNOOZE/DIMMER】to adjust the backlight.
- When operating on batteries only, the backlight will come on shortly (about 10 seconds) when【SNOOZE/DIMMER】is pressed.
LOW BATTERY INDICATION
- Low battery icon due to outdoor humidity, replace batteries in the sensors.
- Low battery icon due to indoor humidity, replace batteries in the weather station.
Note: A low battery icon indicates a low battery level, which may affect normal functions. Please replace new alkaline batteries soon to maintain normal function.
FACTORY RESTART
If there is a malfunction, the Factory Restart is a great way to return your station to “out of the box” condition.
1. FACTORY RESTART
1.) Remove all power (batteries and AC-AC adaptor) from outdoor sensors and the weather station.
2.) Follow the operation “FIRST TIME TO USE” to start the sensor.
IMPORTANT PLACEMENT GUIDELINES
- Mounting under an eave or deck rail works well.
- Mount the remote sensor on the North side where prevent the sun from causing incorrect readings.
- Be sure the outdoor sensor is mounted vertically to drain moisture.
- Mount at least 6 feet in the air for a strong RF (radio frequency)signal.
- To prevent wireless interference, place units at least 3 feet (0.9m) away from electronic devices (TV, computer, microwave, radio, etc.).
- To maximize atomic signal reception, place the weather station away from large metallic items, thick walls, metal surfaces, or other objects that may limit radio communication.
- The maximum wireless transmission range must be within 100 miles of open air, not including walls and floors.
CARE AND MAINTENANCE
- Do not mix old and new batteries.
- Do not mix Alkaline, Standard, Lithium, or rechargeable batteries.
- Always purchase the correct size and grade of battery most suitable for intended use.
- Replace all batteries of a set at the same time.
- Clean the battery contacts and the device’s surface before battery installation.
- Ensure the batteries are installed with correct polarity (+ and -).
- Remove batteries from equipment not to be used for an extended period.
- Promptly remove expired batteries.
SPECIFICATIONS

Recommended For Your Project
VEVOR Weather Station Indoor Outdoor, 7.5 in Large Color Display Manual











Reviews
There are no reviews yet.