Unlock the full potential of your VEVOR PCP Air Compressor with our comprehensive product manual download. Designed for the VEVOR PCP Air Compressor, 4500PSI/30MPa Paintball Air Compressor, DC12V/AC110V Portable PCP Air Compressor, this manual offers step-by-step guidance for seamless setup, troubleshooting, and optimization.
Whether you’re a beginner or a seasoned user, our manual ensures that you can efficiently operate your Manual-Stop PCP Air Rifle Pump, achieving high-pressure results for paintball and scuba tank needs.
Dive into detailed instructions, safety protocols, and maintenance tips, all crafted to enhance your user experience. Download now to enjoy hassle-free operation and peak performance from your VEVOR PCP Air Compressor.
VEVOR PCP Air Compressor User Manual

Product Parameters

PCP Air Compressor Wiring Method


Instructions For Use
- A 11.5-14V DC power supply is required.
- The red terminal is positive (battery +) and black terminal is negative(battery-). Be sure to connect them correctly. Otherwise, the fan will not work, causing damage to the machine due to the temperature being too high.
- The long-time operation is allowed when the fan runs properly, and air typically comes in from the bottom.
- Connect one end of the high-pressure hose to the air outlet of the machine, and tighten the relief screw.
- The piston ring used has an automatic abrasion compensation function. It can recover sealing capability after a short-term preheating process each time. Before the operation, the accompanying pressure measuring chokeplug can be used to plug up the air outlet of the high-pressure hose for 1-20MPA test, which can quickly preheat the machine and find possible abnormal operation of the machine for the first time.
- It is normal when the beginning operating temperature of the machine quickly rises by 60℃. It is only necessary to pay attention to keeping a single operation, not rising by 60℃. It is only necessary to pay attention to keeping a single operation, not more than 30 minutes or 90℃ in daily use, to avoid long-time load operation from burning the motor.
- The maximum pressure of the machine shall not exceed 30MPA. Life will be linearly reduced if the machine is used with overpressure. Considering everything, it is suggested that the safe operating pressure be 25MPA.
- The machine must be started with zero pressure. Upon completion of air inflation, immediately unscrew the relief valve to empty the high-pressure hose, to prevent long-time high temperature and high pressure from causing deformation to the check valve. Never remove the inflation head by force with pressure not emptied, otherwise, it will cause the female head seal ring fly out and failure.
Notes:
- Professional personnel must be on duty during the use process, because high pressure is serious. Immediately shut down the machine and unscrew the relief valve if something is wrong. It is suggested to keep normal 25MPA pressure and lengthen machine life maximally.
- The operating pressure shall be between 11.5-14V, a single operation shall not exceed 30 minutes, and the cylinder temperature shall not exceed 95℃(it may shut down the machine and start the fan only for cooling).
- Ensure that the operation does not exceed 1 minute when the fan does not work and the air inlet is kept out. Otherwise, it will cause serious damage.