{"id":42831,"date":"2024-12-25T09:47:18","date_gmt":"2024-12-25T09:47:18","guid":{"rendered":"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/"},"modified":"2025-07-24T21:05:57","modified_gmt":"2025-07-24T21:05:57","slug":"vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual","status":"publish","type":"product","link":"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/","title":{"rendered":"VEVOR 8KW Diesel Air Heater Muffler Diesel Heater 12V 10L Tank Manual"},"content":{"rendered":"<p>Unlock the full potential of your <a href=\"https:\/\/www.vevor.com\/category-c_106591\/product-p_010170172639\">VEVOR 8KW Diesel Air Heater<\/a> with our comprehensive product manual. Designed specifically for the VEVOR 8KW Diesel Air Heater Muffler Diesel Heater 12V 10L Tank Diesel Parking Heater 8000,W with LCD Monitor for Boat, Bus, RV, and Trailer, this manual is your ultimate guide to seamless setup, optimal operation, and efficient troubleshooting. With step-by-step instructions, clear diagrams, and valuable tips, our manual ensures you can easily install and maintain your heater, maximizing its performance and longevity. Whether you&#8217;re a seasoned technician or a first-time user, you&#8217;ll find our guide user-friendly and informative, making it an indispensable resource for anyone looking to get the most out of their VEVOR Diesel Heater. Download your manual today and experience the convenience and reliability that comes with having expert guidance at your fingertips.<\/p>\n<h2>VEVOR Diesel Air Heater User Manual<\/h2>\n<p><strong>MODELS:<\/strong> KW 2.0, 5.0, 8.0<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-56547\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-air-heater-4-300x202.png!webp\" alt=\"\" width=\"600\" height=\"404\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-air-heater-4-300x202.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-air-heater-4-1024x689.png!webp 1024w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-air-heater-4-768x517.png!webp 768w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-air-heater-4-600x404.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-air-heater-4-64x43.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-air-heater-4.png!webp 1136w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<h3><b>Tips<\/b><\/h3>\n<ol>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">The fuel pipe should be 1.5 meters or 2 meters.<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">The voltage would be better if 11.5 V- 12.8 V.<\/span><\/li>\n<\/ol>\n<h3><b>Application field of the Diesel Air Heater<\/b><\/h3>\n<p><span style=\"font-weight: 400\">The air heater is not affected by the engine and is supplied by the corresponding power for the following vehicles.<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">All kinds of autos and trailers.<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Construction machinery.<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Agricultural machinery.<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Boat, ship, yacht.<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Caravan<\/span><\/li>\n<\/ul>\n<h3><strong>Function<\/strong><\/h3>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u00a0Warm up, defrost the glass.<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Heat and keep warm for the following area:<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u2003&#8212;Driving cab, cabin<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u2003&#8212;Cargo hold<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u2003&#8212;Interior of staff carrier<\/span><span style=\"font-weight: 400\"><br \/>\n<\/span><span style=\"font-weight: 400\"> \u2003&#8212;Caravan<\/span><\/li>\n<\/ul>\n<p><b>The diesel air heater can not be used in the following places and situations<\/b><\/p>\n<p><span style=\"font-weight: 400\">Constant heating for a long time:<\/span><\/p>\n<ul>\n<li><span style=\"font-weight: 400\">Living room, garage<\/span><\/li>\n<li><span style=\"font-weight: 400\">Residential purpose boat<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400\">Heat and dry:<\/span><\/p>\n<ul>\n<li><span style=\"font-weight: 400\">Life (people, animals), blowing hot air directly<\/span><\/li>\n<li><span style=\"font-weight: 400\">Articles and objects<\/span><\/li>\n<li><span style=\"font-weight: 400\">Blow hot air into the container<\/span><\/li>\n<\/ul>\n<h2><b>Diesel Air Heater Safety Instructions<\/b><\/h2>\n<h3><b>Installation<\/b><\/h3>\n<p><span style=\"font-weight: 400\">Prevent the substances around the heater from being damaged and influenced by high temperature.<\/span><\/p>\n<h3><b>Exhaust emission system<\/b><\/h3>\n<p><span style=\"font-weight: 400\">When installing the exhaust vent, prevent the exhaust from entering the heating space through the ventilator, hot air inlet, and window.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Keep the exhaust pipe clear. The exhaust pipe outlet shall be kept from anything flammable, and avoid heating and igniting the flammable goods and loading cargo on the ground.<\/span><\/p>\n<h3><b>The air inlet of combustion-supporting air<\/b><\/h3>\n<p><span style=\"font-weight: 400\">The combustion-supporting air used for heater burning shall not be inhaled from the passenger compartment. The air inlet shall not be blocked, and keep the inlet shall be kept open and clear.<\/span><\/p>\n<p><span style=\"font-weight: 400\">If the air inlet is equipped with a filter, keep the filter clean regularly.<\/span><\/p>\n<h3><b>The heating air inlet<\/b><\/h3>\n<p><span style=\"font-weight: 400\">The heated air shall be composed of fresh or circulating air, which is inhaled from a clean area.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The air inlet pipe shall be protected by a safety fence or other suitable tools, and the pipe shall be clear and open.<\/span><\/p>\n<p><strong>To prevent the people and goods from being damaged, the hot air pipe shall be installed in the place where it could not be easily.<\/strong><\/p>\n<p><b>Safety instructions<\/b><\/p>\n<p><span style=\"font-weight: 400\">The following measures shall not be adopted:<\/span><\/p>\n<ul>\n<li><span style=\"font-weight: 400\">Change the critical component of the diesel air heater.<\/span><\/li>\n<li><span style=\"font-weight: 400\">Make use of the spare parts from other manufacturers without permission.<\/span><\/li>\n<li><span style=\"font-weight: 400\">Disobey the instructions and guide during installation or operation.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400\">Only allow the original attachments and spare parts during installation and maintenance.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The heaters shall not be used in places where flammable vapor or dust, for example:<\/span><\/p>\n<ul>\n<li><span style=\"font-weight: 400\">Fuel depot.<\/span><\/li>\n<li><span style=\"font-weight: 400\">Carbon storehouse.<\/span><\/li>\n<li><span style=\"font-weight: 400\">Timber storehouse.<\/span><\/li>\n<li><span style=\"font-weight: 400\">Granary and similar sites.<\/span><\/li>\n<li><span style=\"font-weight: 400\">Diesel\/petrol station.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400\">The heaters shall be turned off when filling fuel.<\/span><\/p>\n<p><span style=\"font-weight: 400\">If there is a fuel leak or discharge from the heater&#8217;s fuel system, don&#8217;t hesitate to contact the service provider for repair.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Cutting off the electric power is forbidden during the work process to stop the heater from working.<\/span><\/p>\n<h2><b>Product (Diesel Air Heater)<\/b><\/h2>\n<h3><b>Survey<\/b><\/h3>\n<p><span style=\"font-weight: 400\">KW2.0 Air heater (hereinafter referred to as the heater) is independent of the original engine system, it makes use of 12V or 24V direct current to drive.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The heater has two kinds of control modes: Automatic control mode and Manual control mode.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The diesel air heater adopts light diesel and gasoline, which corresponds to the environmental temperature as fuel, and it can be started and operated normally at a temperature above -40\u2103.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The inhaled fresh air is heated to hot air through a heat exchanger by the energy that comes from fuel burning, then blown to where it is needed. This type of heater owns the advantage of compact structure, light weight, high thermal efficiency, economize on electricity and fuel, and easy installation.<\/span><\/p>\n<h2><b>Diesel Air Heater Technical specifications<\/b><\/h2>\n<h3><b>Structural Principle<\/b><\/h3>\n<p><span style=\"font-weight: 400\">After the heater starts, the glow plug comes into operation, the magnetic pump supplies fuel, and the combustion-supporting fan inhales combustion-supporting air from outside the car.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The fuel generates heat by burning in the combustion chamber, which the aluminum heat exchanger takes.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The inner air pushed by the heat exchange fan brings heat to where it is needed through the surface of the heat exchanger, and the combustion emission is discharged through the exhaust pipe.<\/span><\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-56549\" style=\"font-weight: inherit\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/structure-300x189.png!webp\" alt=\"\" width=\"600\" height=\"378\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/structure-300x189.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/structure-768x483.png!webp 768w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/structure-600x378.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/structure-64x40.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/structure.png!webp 807w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<p><span style=\"font-weight: 400\">The structure of the hood-shaped case:<\/span><\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-56548\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/hood-shape-300x191.png!webp\" alt=\"\" width=\"600\" height=\"383\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/hood-shape-300x191.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/hood-shape-600x383.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/hood-shape-64x41.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/hood-shape.png!webp 669w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56550\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/structure-air-heater-300x180.png!webp\" alt=\"\" width=\"600\" height=\"360\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/structure-air-heater-300x180.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/structure-air-heater-64x38.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/structure-air-heater.png!webp 528w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<h2><b>Installation of Fuel Supply System<\/b><\/h2>\n<p><span style=\"font-weight: 400\">Fuel for the diesel air heater can be supplied from the vehicle&#8217;s fuel tank or an additional independent fuel tank. It is not allowed to install the fuel tank in the cab or passenger compartment or any region that is possibly to cause fire if an independent fuel tank is used.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The elevation difference between the air heater and fuel pump, and between the fuel pump and the fuel pump, produces pressure from fuel to the fuel pump. The inner diameter and length of the fuel tube is related to the resistance of the fuel route. Please consider such factors for installation.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56551\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/fuel-pump-300x279.png!webp\" alt=\"\" width=\"600\" height=\"559\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/fuel-pump-300x279.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/fuel-pump-64x60.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/fuel-pump.png!webp 584w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<h2><b>Diesel Air Heater Fuel pump installation<\/b><\/h2>\n<p><span style=\"font-weight: 400\">The fuel pump should be installed in places that can avoid heat radiation from the vehicle parts emitting heat, and in areas with cool air. Its ambient temperature should not exceed 20 \u00b0C.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Directions for the installation of the fuel pump are shown in the following picture.<\/span><\/p>\n<p><span style=\"font-weight: 400\">When installing the fuel pump, please use the fuel pump holder supplied with the heater to hold the pump tight. The pump is fixed with the shock-reducing tightening piece.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56552\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/fuel-pump-installation-300x98.png!webp\" alt=\"\" width=\"600\" height=\"196\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/fuel-pump-installation-300x98.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/fuel-pump-installation-64x21.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/fuel-pump-installation.png!webp 510w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<h2><b>Fuel Filter installation<\/b><\/h2>\n<p><span style=\"font-weight: 400\">The fuel filter should be installed before the fuel inlet port. Please make sure that the fuel flow is followed correctly. Its position shall conform with the above picture.<\/span><\/p>\n<h2><b>Installation of Fuel Tube<\/b><\/h2>\n<p><span style=\"font-weight: 400\">Only the flexible nylon tube, good light-resistance and thermal stability, supplied with the heater can be used as the fuel tube. The inner diameter of the tube is 1\u2019 2mm.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The position of the fuel tube should be away from flying stones and from any heat-emitting parts of the vehicle. A protective device can be installed if necessary. The fuel tube from the fuel pump to the main heater should be in any direction other than downward.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56553\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/fuel-tube-300x84.png!webp\" alt=\"\" width=\"600\" height=\"169\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/fuel-tube-300x84.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/fuel-tube-768x216.png!webp 768w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/fuel-tube-600x169.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/fuel-tube-64x18.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/fuel-tube.png!webp 800w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<p><span style=\"font-weight: 400\">The fuel tube shall be tied in a proper location to make it fixed. The distance between two ties shall be less than 50cm. The fuel tube fittings supplied with the heater should be used for connections between fuel tube and fuel pump, fuel tube and heater, fuel tube and sucking tube of fuel tank and fuel tube and the fuel pump, the fuel tube and the heater, the fuel tube and the sucking tube of the fuel tank, and the fuel tube and the reducing. The fuel tube should tie with fuel tube clamps. Bubbles should be eliminated from the connecting places.<\/span><\/p>\n<h2><b>Installation of Fuel Taking Device<\/b><\/h2>\n<p><span style=\"font-weight: 400\">The openings on the fuel tank (or tank cover)for installation should be appropriate in size, with a trimmed brim and good evenness around the opening.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Good sealing is necessary for the base of the fuel taking tube. The bottom end of the fuel taking tube should be 30mm-40mm from the bottom of the fuel tank to suck enough fuel, and at the same time to avoid sucking in impurities and sediment on the bottom of the fuel tank.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56554\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/fuel-taking-device-300x170.png!webp\" alt=\"\" width=\"600\" height=\"341\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/fuel-taking-device-300x170.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/fuel-taking-device-64x36.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/fuel-taking-device.png!webp 477w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<p><span style=\"font-weight: 400\">If fuel is taken from the fuel pipe to the engine, the fuel pipe from the fuel tank to the fuel filter should be disconnected and re-connected with the thicker pipes of the reducing T.And the thinner pipe of the reducing T should connect the fuel pump of the heater via fuel tube fitting and tube. The installation angle must conform to the following picture, or the normal work of the diesel air heater will be affected.<\/span><\/p>\n<p><span style=\"font-weight: 400\">After installation, the vehicle engine shall be started and then turned off after one minute\u00f4 s work to eliminate air trapped in the fuel sucking pipe.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56555\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/sucking-pipe-300x152.png!webp\" alt=\"\" width=\"600\" height=\"304\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/sucking-pipe-300x152.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/sucking-pipe-600x304.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/sucking-pipe-64x32.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/sucking-pipe.png!webp 710w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<h2><b>Installation of Electrical System<\/b><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56556\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/electric-system-196x300.png!webp\" alt=\"\" width=\"600\" height=\"916\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/electric-system-196x300.png!webp 196w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/electric-system-64x98.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/electric-system.png!webp 518w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<h3><strong>Installation of Combustion Supporting Air Sucking Tube and Exhaust Discharge Tube<\/strong><\/h3>\n<p><span style=\"font-weight: 400\">The combustion-supporting air must be sucked in from external fresh air outside the vehicle. The exhaust from combustion must be discharged into the air through an exhaust tube. Measures must be taken to prevent exhaust from re-entering the vehicle.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The tubes go through the outer wall or holes on the bottom of the vehicle. Measures must be taken to prevent the entry of splashwater. The tubes must be protected and can resist shock permanently.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Only the air inlet and exhaust tubes provided with the heater can be used. The air inlet tube is a corrugate\u00feipe made of an aluminum tube whose it&#8217;s surface is covered by plastic and paper. The exhaust tube is a corrugated stainless steel tube. Please identify them and do not make mistakes during installation. To connect them with the heater, please use the supplied clamps to fix them tightly on the combustion supporting air inlet and exhaust tube vent, respectively.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The protective hood on the air inlet tube and exhaust tube vents must be kept in good condition. Do not damage them or remove them.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The air inlet tube and the exhaust tube should come outwards and downwards from the heater; a 4mm hole shall be prepared at the bottom of the tube to discharge condensation water. If the tube needs to be curved, the radius cannot be smaller than 50mm. Also, each tube&#8217;s sum of all curve angles shall not exceed 270N.<\/span><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56558\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/air-sucking-tube-300x73.png!webp\" alt=\"\" width=\"600\" height=\"146\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/air-sucking-tube-300x73.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/air-sucking-tube-600x146.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/air-sucking-tube-64x16.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/air-sucking-tube.png!webp 616w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<p><span style=\"font-weight: 400\">The opening of the tubes should not be opposite to the direction of the running vehicle.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The tube openings should not be blocked by slurry, rain, snow, or other dirt.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The exhaust tube should be installed far from the plastic parts or other objects with poor thermal resistance of the vehicle body.The exhaust tube should be fixed appropriately. The exhaust vent should be downwards, perpendicular to the road surface with an angle of 90\u00a3 10\u00a3 . To ensure such an angle, the fixing clip for the exhaust tube should be 150mm from the tube end.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56557\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/vent-300x190.png!webp\" alt=\"\" width=\"600\" height=\"381\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/vent-300x190.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/vent-64x41.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/vent.png!webp 473w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<p><b>Warning<\/b><span style=\"font-weight: 400\">: Violation of the above requirements may cause fire.<\/span><\/p>\n<h2><b>Diesel Air Heater Operation and Control<\/b><\/h2>\n<p><span style=\"font-weight: 400\">After the installation, the diesel air heater shall be turned on repeatedly for a few times to make the fuel tube full-filled, so as to avoid staring failure due to a lack of fuel.<\/span><\/p>\n<h2><b>Controller<\/b><\/h2>\n<h3><b>Rotary Knob Panel Instructions<\/b><\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56560\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/rotary-knob-300x201.png!webp\" alt=\"\" width=\"600\" height=\"403\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/rotary-knob-300x201.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/rotary-knob-64x43.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/rotary-knob.png!webp 481w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<h3><strong>Introduction of keys<\/strong><\/h3>\n<p><span style=\"font-weight: 400\">ON-&gt;startup<\/span><\/p>\n<p><span style=\"font-weight: 400\">OFF-&gt; shutdown<\/span><\/p>\n<p><span style=\"font-weight: 400\">Rotary knob-&gt;temperature adjustment and wind speed control<\/span><\/p>\n<h3><b>Lighting instructions<\/b><span style=\"font-weight: 400\">:<\/span><\/h3>\n<p><span style=\"font-weight: 400\">Considering that there is lighting below the ON\/OFF key, the operators will find the rotary knob easily in a dark environment.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The lighting on the outside of the rotary knob will show the temperature value and failure state.<\/span><\/p>\n<h3><b>Key function introduction<\/b><\/h3>\n<p><span style=\"font-weight: 400\">ON-&gt;Please press the ON key gently when the working voltage has satisfied the related conditions.<\/span><\/p>\n<p><span style=\"font-weight: 400\">OFF-&gt; Please press the OFF key gently when the diesel air heater is working.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Rotary knob-&gt;the temperature will rise when the rotary knob is rotated clockwise; at this moment, the red indicators will increase on the outside of the rotary knob. The temperature will go down when the rotary knob is rotated anti-clockwise; at this moment, the red indicators will be reduced on the outside of the rotary knob.<\/span><\/p>\n<h3><b>Fuel filling by hand<\/b><\/h3>\n<p><span style=\"font-weight: 400\">Please rotate the rotary knob clockwise under the OFF state until the red indicators are on, then, please press the OFF button for more than 3 seconds; at this moment, the manual oil pumping will be started. Please press the OFF.<\/span><\/p>\n<h2><b>Installing a picture:<\/b><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56559\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/installing-picture-300x213.png!webp\" alt=\"\" width=\"600\" height=\"426\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/installing-picture-300x213.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/installing-picture-64x45.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/installing-picture.png!webp 591w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56561\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/installing-300x140.png!webp\" alt=\"\" width=\"600\" height=\"280\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/installing-300x140.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/installing-768x359.png!webp 768w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/installing-600x280.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/installing-64x30.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/installing.png!webp 811w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<h2><b>Diesel Air Heater Maintenance<\/b><\/h2>\n<p><span style=\"font-weight: 400\">During the heater&#8217;s running, it tests and checks the operating state and faults throughout the whole course, and the controller constantly shows fault codes on the LCD \/ LED.\u00a0<\/span><\/p>\n<h2><b>The fault code of the LCD screen<\/b><\/h2>\n<h3><b>12V-24V Common Digital Panel Operation Instruction<\/b><\/h3>\n<p><b>\u00a0Indicators<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400\"><b>Status<\/b><span style=\"font-weight: 400\">-&gt; Permanently on upon startup, blinking upon the initialization of shutdown, off upon the completion of shutdown.<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Time-<\/b><span style=\"font-weight: 400\">&gt; Permanently when displaying the time, setting the timed startup or shutdown, and off under other statuses.<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Voltag<\/b><span style=\"font-weight: 400\">e-&gt; Permanently on when displaying voltage or setting the parameters with voltage, and off under other statuses<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Temperature<\/b><span style=\"font-weight: 400\">-&gt; Permanently on when displaying the ambient temperature or setting the operating temperature, and off under other statuses.<\/span><\/li>\n<\/ul>\n<p><b>Key Function<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u25b2-&gt; Under the setting status, press it to raise the parameter to be set; under the non-setting status, press it to raise the operating temperature to be set.<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Set<\/b><span style=\"font-weight: 400\">-&gt; Enter the setting status to adjust parameters and change the machine&#8217;s operating status.<\/span><\/li>\n<li style=\"font-weight: 400\"><b>On\/off<\/b><span style=\"font-weight: 400\"> -&gt; Promptly press it to start up the machine, and the status indicator becomes permanently on; press and hold the key for 2 seconds to shut down the diesel air heater, and the status indicator blinks.<\/span><\/li>\n<li style=\"font-weight: 400\"><b>OK<\/b><span style=\"font-weight: 400\">-&gt; Under the setting status, press it to confirm the current setting value and proceed to the next parameter to be set; under the non-setting status, press it to view the machine&#8217;s status.<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u25bc-&gt; Under the setting status, press it to reduce the parameter to be set; under the non-setting status, press it to reduce the operating temperature to be set.<\/span><\/li>\n<\/ul>\n<h2><b>Description of Setting Parameters (Press the Set Key to Enter)<\/b><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56564\" style=\"font-weight: inherit\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/1-6-300x57.png!webp\" alt=\"\" width=\"600\" height=\"114\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/1-6-300x57.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/1-6-64x12.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/1-6.png!webp 574w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56563\" style=\"font-weight: inherit\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/2-6-235x300.png!webp\" alt=\"\" width=\"600\" height=\"767\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/2-6-235x300.png!webp 235w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/2-6-600x767.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/2-6-64x82.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/2-6.png!webp 655w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56562\" style=\"font-style: inherit;font-weight: inherit\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/3-6-300x154.png!webp\" alt=\"\" width=\"600\" height=\"308\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/3-6-300x154.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/3-6-600x308.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/3-6-64x33.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/3-6.png!webp 623w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<p><span style=\"font-weight: 400\">Note: after all parameters are set, you must press the OK key to quit and save the set parameters. The parameters will not be saved if you quit by pressing the Set key. Please carefully check each digit of the new password, and keep it in mind so you can use it to change parameters next time.<\/span><\/p>\n<p><b>Description of the Diesel air heater&#8217;s Status Query<\/b><\/p>\n<p><span style=\"font-size: 16px\"> <img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56565\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/machine-300x80.png!webp\" alt=\"\" width=\"600\" height=\"159\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/machine-300x80.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/machine-600x159.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/machine-64x17.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/machine.png!webp 715w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/span><\/p>\n<p><b>Manual Fuel Filling Description<\/b><\/p>\n<p><span style=\"font-weight: 400\">Under the non-setting status, press and hold the down arrow key, then press the OK key simultaneously to enter the m\u00e1nual oil pumping interface. When H-OF is displayed, first release the OK key, and then release the down arrow key.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Press the up arrow key to activate manual oil pumping. H-ON will be displayed, and you will hear the oil pumping noise. Press the down arrow key or the Set key to deactivate it and quit the manual oil pumping.<\/span><\/p>\n<p><b>Timed Startup\/Shutdown Description<\/b><\/p>\n<p><span style=\"font-weight: 400\">After setting the run time, press the OK key to enter the timed startup\/shutdown setting function. By default, OF indicates the off status, and please press the up arrow key to activate the ON status. You can press the OK key to set the first group of values, with the hour and minute values for the startup to be set first, and secondly, enter and set the hour and minute values for the shutdown if the values for the startup are set.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Then, press the OK key to enter the second group of values, with similar setting measures as those of the first group. You may specify an interval between the two groups of values. The timing function can only be performed once upon each setting, i.e. if the set timing values are performed, they will be invalid, and you need to reactivate the timing function and set new values for the timing.\u00a0<\/span><\/p>\n<p><b>Temperature Control Mode Switchover Description<\/b><\/p>\n<p><span style=\"font-weight: 400\">Under the non-setting status, press and hold the up arrow key first, then press the Set key simultaneously.<\/span><\/p>\n<p><span style=\"font-weight: 400\">If the panel displays P-xx (xx indicates pump oil volume), it indicates that you have entered the manual temperature control mode. The pump oil volume for operation is restrained within a range between the current and initial pump oil volume.<\/span><\/p>\n<p><span style=\"font-weight: 400\">When you press the keys as mentioned above simultaneously and the panel displays xx \u00b0C (xx indicates temperature value), it suggests that you have entered the automatic temperature control mode and the pump oil volume for operation is restrained within a range between the maximum pump oil volume and the initial pump oil volume.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Under the two modes, the automatic changes of pump oil volume depend on the temperature variation. Still, the difference between the two modes is that, under the automatic mode, the pump oil volume can reach the maximum value set for the parameter, which leads to higher temperature of the machine; under the manual mode, the pump oil volume is limited to the current setting value and can not reach the maximum value set for the parameter, thus the equipment&#8217;s temperature is limited to the selected range, which is more adaptable to specific old-fashioned drivers.<\/span><\/p>\n<p><b>The instructions on the LCD panel<\/b><\/p>\n<p><span style=\"font-weight: 400\">In the condition of not setting, press the raise first, press the confirmation key simultaneously, to keep for more than 3 seconds. Remote control to the code into the interface, display HFA-, press on the remote control to open fire away Control code, the code after the exit of the code interface, the machine into the boot state, if the code does not enter the boot failure state. The timeout is wrong code, automatically withdraw from the code.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56566\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/lcd-300x96.png!webp\" alt=\"\" width=\"600\" height=\"192\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/lcd-300x96.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/lcd-768x246.png!webp 768w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/lcd-600x192.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/lcd-64x21.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/lcd.png!webp 799w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<h2><b>Instructions for Use of 12V &#8211; 24V General LCD Panel<\/b><\/h2>\n<h3><b>Button function<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u25ba &gt; In the setting state, increase the setting parameter; in the non-setting state, increase the working temperature or oil mass.<\/span><\/li>\n<li style=\"font-weight: 400\"><b>ON\/OFF<\/b><span style=\"font-weight: 400\"> -&gt; Short press start-up button, LCD screen displays ON, and long press shutdown button for 3 seconds, LCD screen displays OFF.<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u25ba-&gt; In setting state, decrease the setting parameters; in non-setting state, decrease working temperature or oil mass. The basic operation can be referred to in the above state, and the following operation descriptions can be used for settings.\u00a0<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Setting<\/b><span style=\"font-weight: 400\"> -&gt; Enter the setting state, adjust setting parameters, and change the working status of the machine\u00a0<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Confirm<\/b><span style=\"font-weight: 400\"> -&gt; Under the setting state, confirm the current setting value and enter the next parameter setting. View the machine state in the non-setting state.\u00a0<\/span><\/li>\n<\/ul>\n<h3><b>Query machine status<\/b><\/h3>\n<p><b>(Keep pressing the confirm button to switch one state at a time to make it display cyclically)<\/b><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56567\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/machine-status-300x56.png!webp\" alt=\"\" width=\"600\" height=\"113\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/machine-status-300x56.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/machine-status-600x113.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/machine-status-64x12.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/machine-status.png!webp 712w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<h3><b>Description of fuel filling in manual mode<\/b><\/h3>\n<p><span style=\"font-weight: 400\">Under the shutdown state, press the down-regulation button and the setting button simultaneously to conduct filling manually, which displays H of, and after releasing, press the up-regulation button. It displays H of the oil pump starts to work.<\/span><\/p>\n<p><span style=\"font-weight: 400\">You can hear the oil pump working, and the oil pump icon lights up. Press the down-regulation button to display H oF, exit fuel filling, and the oil pump icon disappears. The process of line evacuation shall be done under watch. When the oil reaches the position of the oil inlet of the machine, it can be stopped. If too much oil enters the machine, there will be black smoke when igniting.<\/span><\/p>\n<h2><b>Description of temperature control mode switching<\/b><\/h2>\n<p><span style=\"font-weight: 400\">Press the up-regulation button and confirm button simultaneously to conduct the temperature control mode switch. There are manual temperature control modes (oil mass adjustment t shows P-15, number represents the oil mass) and automatic temperature control modes (temperature adjustment shows 25\u00b0, number represents the temperature).<\/span><\/p>\n<p><span style=\"font-weight: 400\">The difference between two modes is that: in automatic mode, pump oil amount can reach the maximum upon parameter setting and the machine heat is higher, the manual pump oil amount is limited to the current setting value and will not reach the maximum oil value set by the parameter, which makes gears clearly shown and is very convenient for the part old hands.<\/span><\/p>\n<h2><b>Description of remote control code matching<\/b><\/h2>\n<p><span style=\"font-weight: 400\">In the shutdown state, press the power and confirm buttons simultaneously on the remote control first. The text &#8221; waiting for matching appears on the remote control, then keep pressing the up-regulation and down-regulation buttons of the LCD panel.<\/span><\/p>\n<p><span style=\"font-weight: 400\">When showing HFR, it enters the remote control code matching interface. Upon success, it will automatically exit the interface, then it shows normal working parameters. If the code matching failed, it would not enter the normal state of displaying working parameters.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The code matching state will be automatically exited when it does not receive remote control code for a long time.<\/span><\/p>\n<h2><b>Description of parameter setting procedure<\/b><\/h2>\n<p><b>(Press the setting button to enter the setting state)<\/b><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56569\" style=\"font-weight: inherit\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/6-3-241x300.png!webp\" alt=\"\" width=\"600\" height=\"747\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/6-3-241x300.png!webp 241w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/6-3-600x747.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/6-3-64x80.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/6-3.png!webp 622w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56568\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/7-3-283x300.png!webp\" alt=\"\" width=\"600\" height=\"637\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/7-3-283x300.png!webp 283w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/7-3-600x637.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/7-3-64x68.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/7-3.png!webp 698w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><span style=\"font-weight: 400\">Precautions: For clock time, set the start-up and shutdown times, and they will take effect immediately after setting them. After setting all parameters after the administrator&#8217;s password, you must press the confirm button until item 9 to exit, through which we could save the set parameters.<\/span><\/p>\n<p><span style=\"font-weight: 400\">If quitting midway, previous adjustment data will be lost and invalid. Please check each new digit of the password carefully and save it, through which you can enter in the parameter modification next time.<\/span><\/p>\n<h2><b>Instructions for Use of 12V &#8211; 24V General LCD Panel<\/b><\/h2>\n<h3><b>Button function<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">-&gt;In non-setting state, increase the working temperature or oil mass. In the setting state, increase the setting parameter.<\/span><\/li>\n<li style=\"font-weight: 400\"><b>On\/Off<\/b><span style=\"font-weight: 400\">-&gt;. Long press for 3 seconds to start-up, the screen displays, and long press 3 seconds to shutdown, the screen displays off<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">-&gt; In non-setting state, decrease the working temperature or oil mass. The above state is sufficient for the basic operation of decreasing the setting parameters in the setting state. Other operations are described as follows.<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Parameter settings<\/b><span style=\"font-weight: 400\"> -&gt; Press the up-regulation button for a long time to enter the setting state. The parameters can be adjusted to change the working status of the machine.<\/span><\/li>\n<li style=\"font-weight: 400\"><b>In the parameter confirmation<\/b><span style=\"font-weight: 400\"> -&gt; setting state, confirm the current setting value by pressing On\/Off button to enter the next parameter setting. Press the On\/Off button to view the machine&#8217;s running state in the non-setting state.<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Remote control code matching<\/b><span style=\"font-weight: 400\"> -&gt; Press the down-regulation button for a long time to enter the remote control pairing state, and press remote control power button for pairing. Please refer to the description later for detailed operation.<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Temperature control conversion<\/b><span style=\"font-weight: 400\"> -&gt; Switch the temperature control mode by simultaneously pressing and holding the up-regulation and On\/Off buttons. Please refer to the following description for details.<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Fuel filling<\/b><span style=\"font-weight: 400\"> -&gt; Press and hold down-regulation button and On\/Off button simultaneously to start the fuel filling function, as described later.<\/span><\/li>\n<\/ul>\n<p><b>Query machine status (keep pressing the On\/Off button to switch one state at a time to make it display cyclically)<\/b><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56570\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/machine-status-query-300x52.png!webp\" alt=\"\" width=\"600\" height=\"104\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/machine-status-query-300x52.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/machine-status-query-768x133.png!webp 768w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/machine-status-query-600x104.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/machine-status-query-64x11.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/machine-status-query.png!webp 909w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<h3><b>Description of fuel filling in manual mode<\/b><\/h3>\n<p><span style=\"font-weight: 400\">Under the shutdown state, press the down-regulation button and On\/Off button simultaneously to conduct fuel filling manually, which displays oF, and after releasing, press the up-regulation button. It displays H oF, and the oil pump starts to work. You can hear the oil pump working, and the oil pump icon lights up. Press the down-regulation button to display H oF, exit fuel filling, the oil pump icon disappears.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The process of line air evacuation shall be done under watch, when the oil reaches the position of the oil inlet of the machine, it can be stopped. If there is too much oil enters the machine, there will be black smoke when igniting.<\/span><\/p>\n<h3><b>Description of temperature control mode switching<\/b><\/h3>\n<p><span style=\"font-weight: 400\">Press the up-regulation button and On\/Off button simultaneously to conduct the temperature control mode switch. There are manual temperature control mode (oil mass adjustment t shows P-15, number represents the oil mass) and automatic temperature control mode (temperature adjustment shows 25\u00b0C, number represents the temperature). The difference between two modes is that: in automatic mode, pump oil amount can reach the maximum upon parameter setting and the machine heat is higher, the manual pump oil amount is limited to the current setting value and will not reach the maximum oil value set by the parameter, which makes gears clearly shown and is very convenient for the part old hands.<\/span><\/p>\n<h3><b>Description of remote control code matching<\/b><\/h3>\n<p><span style=\"font-weight: 400\">In the shutdown state, long-press the LCD panel down-regulation button. Enter the remote control code matching interface to make it display FR-, then press the On button of the remote control to transmit the remote control code, and successful code matching will make it automatically exit the code interface.<\/span><\/p>\n<p><span style=\"font-weight: 400\">If the code matching fails, it will not enter the start-up state. The code matching state will be automatically exited when it does not receive remote control code for a long time.<\/span><\/p>\n<h3><b>Description of parameter setting procedure<\/b><\/h3>\n<p><b>(Press the up-regulation button to enter the setting state)<\/b><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56572\" style=\"font-weight: inherit\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/parameter-setting-292x300.png!webp\" alt=\"\" width=\"600\" height=\"617\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/parameter-setting-292x300.png!webp 292w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/parameter-setting-600x617.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/parameter-setting-64x66.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/parameter-setting.png!webp 628w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56571\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/parameter-setting-1-251x300.png!webp\" alt=\"\" width=\"600\" height=\"717\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/parameter-setting-1-251x300.png!webp 251w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/parameter-setting-1-600x717.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/parameter-setting-1-64x76.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/parameter-setting-1.png!webp 617w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><span style=\"font-weight: 400\">Precautions: For clock time, set the start-up and shutdown times, and it will take effect immediately after setting them. After setting all parameters after the administrator&#8217;s password, you must press the confirm button until to item 9 to exit, through which we can save the set parameters. If quitting midway, previous adjustment data will be lost and invalid.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Please carefully check each new password digit and save it, so you can enter the parameter modification next time.<\/span><\/p>\n<h2>Diesel Air Heater Main Board Fault Code Description<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56573\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/main-board-300x280.png!webp\" alt=\"\" width=\"600\" height=\"559\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/main-board-300x280.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/main-board-600x559.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/main-board-64x60.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/main-board.png!webp 737w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<h2><b>Bi-directional Remote Control Operation Instructions<\/b><\/h2>\n<h3><b>Remote control pairing operation<\/b><\/h3>\n<p><span style=\"font-weight: 400\">In the shutdown state, first long-press the down-regulation button on the LCD panel that needs to be paired first. Showing HFR means it enters the remote control code matching interface.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Then press the power button and confirm button on the remote control at the same time, the text &#8221; waiting &#8221; appears on the remote control, and the remote control and switch enter the automatic matching process. After successful code matching, it will automatically exit the code interface and display the normal working parameters.<\/span><\/p>\n<p><span style=\"font-weight: 400\">If the code matching failed, it would not enter the normal state of displaying working parameters. The code matching state will be automatically exited when it does not receive remote control code over time.<\/span><\/p>\n<h3><b>Temperature control mode switching<\/b><\/h3>\n<p><span style=\"font-weight: 400\">When the temperature control mode is selected by remote control, only press the up-regulation and down-regulation buttons simultaneously to display the temperature when switching to automatic temperature control, and the oil mass will be displayed if the temperature is controlled manually.<\/span><\/p>\n<h3><b>Working status adjustment<\/b><\/h3>\n<p><span style=\"font-weight: 400\">The working status of the heater can be adjusted at any time by remote control. The methods are as follows:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400\"><b>Up-regulation button:<\/b><span style=\"font-weight: 400\"> Increase the pump oil amount (manual temperature control mode) or raise the setting temperature to increase the output temperature of the heater.<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Down-regulation button:<\/b><span style=\"font-weight: 400\"> Decrease the pump oil amount (manual temperature control mode) or reduce the setting temperature to decrease the output temperature of the heater.<\/span><\/li>\n<\/ul>\n<h3><b>Instructions for the use of the bi-directional remote control receiving<\/b><\/h3>\n<p><b>Introduction of buttons<\/b><span style=\"font-weight: 400\">:<\/span><\/p>\n<p><span style=\"font-weight: 400\">On\/Off-&gt;long press On\/Off<\/span><\/p>\n<h3><b>Lighting instructions<\/b><\/h3>\n<p><span style=\"font-weight: 400\">Light is under the switch button; long lighting indicates the start-up, and flashing suggests a fault. Introduction of button functions<\/span><\/p>\n<p><span style=\"font-weight: 400\">Start-up-&gt; When the operating voltage meets the conditions, press ON\/OFF for a long time.<\/span><\/p>\n<h3><b>Fuel filling in manual mode<\/b><\/h3>\n<p><span style=\"font-weight: 400\">In shutdown state, start the manual oil pumping by pressing On\/off button 5 times continuously and quickly. Please gently press the On\/Off button to stop the oil pumping when the air is removed from the oil circuit.<\/span><\/p>\n<p><span style=\"font-weight: 400\">This process requires observation of a specially-assigned person to avoid excessive fuel entering the machine and black smoke at start-up.<\/span><\/p>\n<h3><b>Remote control pairing<\/b><\/h3>\n<p><span style=\"font-weight: 400\">In the start-up state, press On\/Off button 5 times continuously and quickly, the indicator light flashing means it has entered the remote control pairing waiting state. At the same time, press the power button + setting button on the remote control for a long time to start the remote control pairing. Wait for auto-completion of pairing to exit.<\/span><\/p>\n<h2><b>Bi-directional Remote Control Operation Instructions<\/b><\/h2>\n<h3><b>Operation instructions for buttons<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400\"><b>On\/Off button<\/b><span style=\"font-weight: 400\">: Press and hold for 2 seconds to turn on, or turn off<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Confirm button<\/b><span style=\"font-weight: 400\">: View the host working status<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Up-regulation button:<\/b><span style=\"font-weight: 400\"> Increase the oil mass or temperature according to the temperature control method.<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Down-regulation button:<\/b><span style=\"font-weight: 400\"> Increase the oil mass or temperature according to the temperature control method.<\/span><\/li>\n<\/ul>\n<h3><b>Remote control pairing operation<\/b><\/h3>\n<p><span style=\"font-weight: 400\">First, the receiving part, which needs to be paired, is put into the waiting pairing state. Then press the power and confirm buttons on the remote control simultaneously, and the interface of waiting for pairing appears on the remote control.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The remote control and the switch enter the automatic pairing process. The code matching interface will be automatically exited after the successful code matching, and the normal working parameters will be displayed. If the code matching failed, it would not enter the normal state of displaying working parameters. The code matching state will be automatically exited when it does not receive remote control code over time.<\/span><\/p>\n<h3><b>Temperature control mode switching<\/b><\/h3>\n<p><span style=\"font-weight: 400\">When the temperature control mode is selected by remote control, only press the up-regulation and down-regulation buttons simultaneously to display the temperature when switching to automatic temperature control, and the oil mass will be displayed if the temperature is controlled manually.<\/span><\/p>\n<h3><b>Working status adjustment<\/b><\/h3>\n<p><span style=\"font-weight: 400\">The working status of the heater can be adjusted at any time by remote control. The methods are as follows: Increase the pump oil amount (manual temperature control mode) by using the up-regulation button, or raise the setting temperature to increase the output temperature of the heater.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Decrease the of pump oil (manual temperature control mode) by using the down-regulation button or reduce the setting temperature to decrease the output temperature of the heater.<\/span><\/p>\n<h2><b>Instructions for Use of 12V &#8211; 24V General LCD Panel<\/b><\/h2>\n<h3><b>Button function<\/b><\/h3>\n<ul>\n<li style=\"font-weight: 400\"><b>Setting<\/b><span style=\"font-weight: 400\"> -&gt; Enter the setting state, adjust the setting parameters, and change the working status of the machine<\/span><\/li>\n<li style=\"font-weight: 400\"><b>Confirm<\/b><span style=\"font-weight: 400\"> -&gt; OK -&gt; Under the setting state, confirm the current setting value and enter the next parameter setting. View the machine state in the non-setting state.<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u25b2-&gt; In the setting state, increase the setting parameter; in the non-setting state, increase the set working temperature.<\/span><\/li>\n<li style=\"font-weight: 400\"><b>On\/Off<\/b><span style=\"font-weight: 400\">-&gt; Short-press the button to turn on; the status indicator light will always be on. Long-press the button to turn off for 2 seconds, and the status indicator light will flash.<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">\u25bc-&gt; In the setting state, decrease the setting parameter, and lower the set working temperature in the non-setting state.<\/span><\/li>\n<\/ul>\n<h3><b>Description of remote control code matching<\/b><\/h3>\n<p><span style=\"font-weight: 400\">In a non-setting state, press the up-regulation button first and press the confirm button simultaneously for more than 3 seconds.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Entering the remote control code matching interface, it displays HFA-. Press the open button on the remote control to transmit the remote control code, exit the code interface after code matching, and the machine enters the start-up state.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The machine will not enter the start-up state if the code matching fails. It will exit the code-matching state after overtime code-matching work.\u00a0<\/span><\/p>\n<h3><b>Description of setting parameters<\/b><\/h3>\n<p><b>(Press the setting button to enter, and the status icon corresponding to the display screen is lit)<\/b><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56575\" style=\"font-weight: inherit\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/desc-1-1-300x297.png!webp\" alt=\"\" width=\"600\" height=\"594\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/desc-1-1-300x297.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/desc-1-1-150x150.png!webp 150w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/desc-1-1-768x760.png!webp 768w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/desc-1-1-600x594.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/desc-1-1-100x100.png!webp 100w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/desc-1-1-64x63.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/desc-1-1.png!webp 788w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56574\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/setting-parameters-desc-300x185.png!webp\" alt=\"\" width=\"600\" height=\"369\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/setting-parameters-desc-300x185.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/setting-parameters-desc-768x472.png!webp 768w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/setting-parameters-desc-600x369.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/setting-parameters-desc-64x39.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/setting-parameters-desc.png!webp 969w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\u00a0<b>Precautions<\/b><span style=\"font-weight: 400\">: After all the parameters are set, you must press the confirm button to exit before saving the settings. The parameters will not be stored if you press the confirm button to exit.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Please carefully check and save each new password digit, which you can enter into the parameter modification next time.<\/span><\/p>\n<h2><b>Query the machine status description.<\/b><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-56576\" src=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/status-query-300x52.png!webp\" alt=\"\" width=\"600\" height=\"104\" srcset=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/status-query-300x52.png!webp 300w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/status-query-768x133.png!webp 768w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/status-query-600x104.png!webp 600w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/status-query-64x11.png!webp 64w, https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/status-query.png!webp 866w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<h2><b>Description of fuel filling in manual mode<\/b><\/h2>\n<p><span style=\"font-weight: 400\">In the non-setting state, press the down-regulation button first and then the confirm button to enter the manual pump interface. When it displays H-of, release the confirm button first and then release the down-regulation button.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Press the up-regulation button to start the manual pump oil, and it displays the H-on. You can hear the working sound of the oil pump, and the oil pump icon lit. Press the down-regulation or setting buttons to close and exit the manual pump, and the oil pump icon disappears.<\/span><\/p>\n<h3><b>Timing switch description<\/b><\/h3>\n<p><span style=\"font-weight: 400\">After the running time is set, press confirm button to enter the timing switch function setting, which defaults to &#8220;of&#8221; off state, press up-regulation button to start &#8220;on&#8221; state, press confirm button to set the first group about the hours and minutes of start-up time, and then enter the setting of hours and minutes of shutdown time after confirmation.<\/span><\/p>\n<p><span style=\"font-weight: 400\">Press the confirm button to enter the second group. The setting method is the same as above. Set the hours and minutes of start-up time, then the hours and minutes of shutdown time.<\/span><\/p>\n<p><span style=\"font-weight: 400\">A time interval may be set between the two sets of timings. The timing function is only run once. After this time, the current timing will be turned off. Please turn it on again and set the time for the next time. The alarm clock icon lit up after the timing setting and disappeared at the end of the timing.<\/span><\/p>\n<h3><b>Description of temperature control mode switching<\/b><\/h3>\n<p><span style=\"font-weight: 400\">In the non-setting state, press and hold the up-regulation button first and then press the setting button to display P-x.x (xx represents the pump oil amount), i.e., entering the manual temperature control mode.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The pump oil amount is limited to the current setting, which is the initial amount. When you press the 2 button above, XX is displayed. C (xx stands for temperature value), the automatic temperature control mode is entered, and the pump oil amount is controlled to run between the maximum pump oil amount and the initial pump oil amount.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The automatic change of the pump oil amount in two modes depends on the temperature change. The difference between the two modes is that the pump oil amount in automatic mode can reach the maximum value in the parameter setting, and the machine&#8217;s heat is high.<\/span><\/p>\n<p><span style=\"font-weight: 400\">The pump oil amount in manual mode is limited to the current setting value and will not reach the maximum value in the parameter setting. The diesel air heater is limited to the range of choice, taking into account the usage habits of some old drivers.<\/span><\/p>\n<div id=\"vevor-goods-card-container_1\"><div id=\"translate_map\" style=\"height:0;overflow:hidden;\"><div id='VkVWT1IgOEtXIERpZXNlbCBIZWF0ZXIsIDEyVi8yNFYgQWxsIGluIE9uZSBEaWVzZWwgQWlyIEhlYXRlciwgQmx1ZXRvb3RoIEFQUCBDb250cm9sLCBSZW1vdGUgQ29udHJvbCBhbmQgRGlzcGxheSBTY3JlZW4sIENPIEFsYXJtLCBGYXN0IEhlYXRpbmcgSG9yaXpvbnRhbCBQb3J0YWJsZSBEaWVzZWwgSGVhdGVyIGZvciBWZWhpY2xlcywgR2FyYWdl'>VEVOR 8KW Diesel Heater, 12V\/24V All in One Diesel Air Heater, Bluetooth APP Control, Remote Control and Display Screen, CO Alarm, Fast Heating Horizontal Portable Diesel Heater for Vehicles, Garage<\/div><div id='VkVWT1IgMktXIERpZXNlbCBIZWF0ZXIsIDEyVi8yNFYgQWxsIGluIE9uZSBEaWVzZWwgQWlyIEhlYXRlciwgd2l0aCBCbHVldG9vdGggQVBQIENvbnRyb2wsIFJlbW90ZSBDb250cm9sIGFuZCBEaXNwbGF5IFNjcmVlbiwgQ08gQWxhcm0sIEZhc3QgSGVhdGluZyBQb3J0YWJsZSBEaWVzZWwgSGVhdGVyIGZvciBWZWhpY2xlcyBhbmQgT3V0ZG9vcnM='>VEVOR 2KW Diesel Heater, 12V\/24V All in One Diesel Air Heater, with Bluetooth APP Control, Remote Control and Display Screen, CO Alarm, Fast Heating Portable Diesel Heater for Vehicles and Outdoors<\/div><div id='VkVWT1IgOEtXIERpZXNlbCBIZWF0ZXIsIDEyVi8yNFYgQWxsIGluIE9uZSBEaWVzZWwgQWlyIEhlYXRlciwgQmx1ZXRvb3RoIEFQUCBDb250cm9sLCBSZW1vdGUgQ29udHJvbCBhbmQgRGlzcGxheSBTY3JlZW4sIENPIEFsYXJtLCBGYXN0IEhlYXRpbmcgVmVydGljYWwgUG9ydGFibGUgRGllc2VsIEhlYXRlciBmb3IgVmVoaWNsZXMsIEdhcmFnZQ=='>VEVOR 8KW Diesel Heater, 12V\/24V All in One Diesel Air Heater, Bluetooth APP Control, Remote Control and Display Screen, CO Alarm, Fast Heating Vertical Portable Diesel Heater for Vehicles, Garage<\/div><div id='VkVWT1IgOEtXIERpZXNlbCBIZWF0ZXIsIDEyVi8yNFYgQWxsIGluIE9uZSBEaWVzZWwgQWlyIEhlYXRlciwgd2l0aCBCbHVldG9vdGggQVBQIENvbnRyb2wsIFJlbW90ZSBDb250cm9sIGFuZCBEaXNwbGF5IFNjcmVlbiwgQ08gQWxhcm0sIEZhc3QgSGVhdGluZyBQb3J0YWJsZSBEaWVzZWwgSGVhdGVyIGZvciBWZWhpY2xlcyBhbmQgR2FyYWdl'>VEVOR 8KW Diesel Heater, 12V\/24V All in One Diesel Air Heater, with Bluetooth APP Control, Remote Control and Display Screen, CO Alarm, Fast Heating Portable Diesel Heater for Vehicles and Garage<\/div><\/div><h2>Recommended For Your Project<\/h2><\/div>\n<p>&nbsp;<\/p>\n<a href=\"https:\/\/d2v0huudrf11kh.cloudfront.net\/vevor-center-goods\/DieselAirHeaterManual_1656042936102.pdf\" class=\"download-link\" title=\"VEVOR 8KW Diesel Air Heater Muffler Diesel Heater 12V 10L Tank Manual\" id=\"download-link-42838\" target=\"_blank\" data-redirect=\"false\" rel=\"nofollow\" data-e-disable-page-transition=\"true\" download=\"DieselAirHeaterManual_1656042936102.pdf\" >VEVOR 8KW Diesel Air Heater Muffler Diesel Heater 12V 10L Tank Manual<\/a>\n","protected":false},"excerpt":{"rendered":"<p><strong>Efficient Diesel Heater:<\/strong> Heater Power: 8KW; Rated Voltage: 12V; Heater Working Temp: -40\u2103~+20\u2103; Oil Pump Working Temp: -40\u2103~+20\u2103. On cold winter days, we have got you covered with this diesel air heater to warm your car and eliminate the windows&#8217; frost. With fast heating and low noise, the aluminum heater runs smoothly in any harsh environment.<br \/>\n<strong>Low Energy Consumption:<\/strong> Fuel Consumption: 0.18-0.67 (L\/H); Fuel Gasoline: Diesel Only. The diesel heater features an oil pump that precisely controls the fuel inlet for thorough combustion, saving energy while working smoothly. A full 10L\/2.6 gal fuel tank will power your heater for up to 100 hours, ensuring low emissions and long-term running.<br \/>\n<strong>Intelligent LCD Control:<\/strong> Our diesel parking heater is equipped with an intelligent LCD monitor for digital temperature control. Once activated, the heater&#8217;s timer and thermostat can be automatically or manually adjusted by the built-in LCD panel. Moreover, a timing heating function is available for presetting the heating switch time.<br \/>\n<strong>Effortless Installation:<\/strong> Complete Accessories: 1 x Oil Pump, 1 x 10L Tank, 1 x LCD Switch, 1 x Silencer, 1 x Mainline Beam, 1 x Oil Filter, 1 x Air Filter, 1 x Inlet Pipe, 1 x Exhaust Pipe, 1 x Installation Kit. The full accessories set makes it a breeze to install this parking heater in your vehicle. It can be flexibly installed in the passenger room, trunk, or under the container.<br \/>\n<strong>Wide Application:<\/strong> As a warming companion for any diesel vehicle, the bunk heater is widely used to heat the cabs of cars, RVs, caravans, trucks, ships, etc. This heating device blows out warm air independently without causing wear and tear or carbon deposits in the engine, thus prolonging engine life by 30%. With the compact and portable design, it is also an excellent choice for home and shop.<\/p>\n","protected":false},"featured_media":42830,"comment_status":"open","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[6793],"product_tag":[],"class_list":{"0":"post-42831","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-garage-equipment-manual","7":"desktop-align-left","8":"tablet-align-left","9":"mobile-align-left","11":"first","12":"instock","13":"downloadable","14":"shipping-taxable","15":"purchasable","16":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.3 (Yoast SEO v25.3) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>VEVOR 8KW Diesel Air Heater Manual, 12V 10L Tank<\/title>\n<meta name=\"description\" content=\"Download the VEVOR 8KW Diesel Air Heater manual for easy setup, operation, and troubleshooting. Perfect for Boat, Bus, RV, and Trailer. Get expert guidance!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"VEVOR 8KW Diesel Air Heater Muffler Diesel Heater 12V 10L Tank Manual\" \/>\n<meta property=\"og:description\" content=\"Download the VEVOR 8KW Diesel Air Heater manual for easy setup, operation, and troubleshooting. Perfect for Boat, Bus, RV, and Trailer. Get expert guidance!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/\" \/>\n<meta property=\"og:site_name\" content=\"VEVOR Blog\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-24T21:05:57+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-heater-m100-1.2-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1600\" \/>\n\t<meta property=\"og:image:height\" content=\"1600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"31 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/\",\"url\":\"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/\",\"name\":\"VEVOR 8KW Diesel Air Heater Manual, 12V 10L Tank\",\"isPartOf\":{\"@id\":\"https:\/\/www.vevor.com\/diy-ideas\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-heater-m100-1.2-1.jpg\",\"datePublished\":\"2024-12-25T09:47:18+00:00\",\"dateModified\":\"2025-07-24T21:05:57+00:00\",\"description\":\"Download the VEVOR 8KW Diesel Air Heater manual for easy setup, operation, and troubleshooting. Perfect for Boat, Bus, RV, and Trailer. Get expert guidance!\",\"breadcrumb\":{\"@id\":\"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/#primaryimage\",\"url\":\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-heater-m100-1.2-1.jpg\",\"contentUrl\":\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-heater-m100-1.2-1.jpg\",\"width\":1600,\"height\":1600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Homepage\",\"item\":\"https:\/\/www.vevor.com\/diy-ideas\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/www.vevor.com\/diy-ideas\/shop\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"VEVOR 8KW Diesel Air Heater Muffler Diesel Heater 12V 10L Tank Manual\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.vevor.com\/diy-ideas\/#website\",\"url\":\"https:\/\/www.vevor.com\/diy-ideas\/\",\"name\":\"VEVOR Blog\",\"description\":\"Creative DIY Projects and Tutorials\",\"publisher\":{\"@id\":\"https:\/\/www.vevor.com\/diy-ideas\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.vevor.com\/diy-ideas\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.vevor.com\/diy-ideas\/#organization\",\"name\":\"VEVOR Blog\",\"url\":\"https:\/\/www.vevor.com\/diy-ideas\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.vevor.com\/diy-ideas\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/10\/VEVOR-Logo-New.png\",\"contentUrl\":\"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/10\/VEVOR-Logo-New.png\",\"width\":1029,\"height\":126,\"caption\":\"VEVOR Blog\"},\"image\":{\"@id\":\"https:\/\/www.vevor.com\/diy-ideas\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"VEVOR 8KW Diesel Air Heater Manual, 12V 10L Tank","description":"Download the VEVOR 8KW Diesel Air Heater manual for easy setup, operation, and troubleshooting. Perfect for Boat, Bus, RV, and Trailer. Get expert guidance!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/","og_locale":"en_US","og_type":"article","og_title":"VEVOR 8KW Diesel Air Heater Muffler Diesel Heater 12V 10L Tank Manual","og_description":"Download the VEVOR 8KW Diesel Air Heater manual for easy setup, operation, and troubleshooting. Perfect for Boat, Bus, RV, and Trailer. Get expert guidance!","og_url":"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/","og_site_name":"VEVOR Blog","article_modified_time":"2025-07-24T21:05:57+00:00","og_image":[{"width":1600,"height":1600,"url":"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-heater-m100-1.2-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"31 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/","url":"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/","name":"VEVOR 8KW Diesel Air Heater Manual, 12V 10L Tank","isPartOf":{"@id":"https:\/\/www.vevor.com\/diy-ideas\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/#primaryimage"},"image":{"@id":"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/#primaryimage"},"thumbnailUrl":"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-heater-m100-1.2-1.jpg","datePublished":"2024-12-25T09:47:18+00:00","dateModified":"2025-07-24T21:05:57+00:00","description":"Download the VEVOR 8KW Diesel Air Heater manual for easy setup, operation, and troubleshooting. Perfect for Boat, Bus, RV, and Trailer. Get expert guidance!","breadcrumb":{"@id":"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/#primaryimage","url":"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-heater-m100-1.2-1.jpg","contentUrl":"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-heater-m100-1.2-1.jpg","width":1600,"height":1600},{"@type":"BreadcrumbList","@id":"https:\/\/www.vevor.com\/diy-ideas\/product\/vevor-8kw-diesel-air-heater-muffler-diesel-heater-12v-10l-tank-manual\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Homepage","item":"https:\/\/www.vevor.com\/diy-ideas\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.vevor.com\/diy-ideas\/shop\/"},{"@type":"ListItem","position":3,"name":"VEVOR 8KW Diesel Air Heater Muffler Diesel Heater 12V 10L Tank Manual"}]},{"@type":"WebSite","@id":"https:\/\/www.vevor.com\/diy-ideas\/#website","url":"https:\/\/www.vevor.com\/diy-ideas\/","name":"VEVOR Blog","description":"Creative DIY Projects and Tutorials","publisher":{"@id":"https:\/\/www.vevor.com\/diy-ideas\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.vevor.com\/diy-ideas\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.vevor.com\/diy-ideas\/#organization","name":"VEVOR Blog","url":"https:\/\/www.vevor.com\/diy-ideas\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.vevor.com\/diy-ideas\/#\/schema\/logo\/image\/","url":"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/10\/VEVOR-Logo-New.png","contentUrl":"https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/10\/VEVOR-Logo-New.png","width":1029,"height":126,"caption":"VEVOR Blog"},"image":{"@id":"https:\/\/www.vevor.com\/diy-ideas\/#\/schema\/logo\/image\/"}}]}},"spectra_custom_meta":{"_yoast_indexnow_last_ping":["1753391157"],"_sku":["ZCJRQ12V8KWYJXS01V0"],"total_sales":["0"],"_tax_status":["taxable"],"_tax_class":[""],"_manage_stock":["no"],"_backorders":["no"],"_sold_individually":["no"],"_virtual":["no"],"_downloadable":["yes"],"_download_limit":["-1"],"_download_expiry":["-1"],"_thumbnail_id":["42830"],"_stock":[null],"_stock_status":["instock"],"_wc_average_rating":["0"],"_wc_review_count":["0"],"_downloadable_files":["a:1:{s:36:\"dd0f6924-45b7-4574-8e01-8dbfbcd096f5\";a:4:{s:2:\"id\";s:36:\"dd0f6924-45b7-4574-8e01-8dbfbcd096f5\";s:4:\"name\";s:69:\"VEVOR 8KW Diesel Air Heater Muffler Diesel Heater 12V 10L Tank Manual\";s:4:\"file\";s:96:\"https:\/\/d2v0huudrf11kh.cloudfront.net\/vevor-center-goods\/DieselAirHeaterManual_1656042936102.pdf\";s:7:\"enabled\";b:1;}}"],"_product_version":["9.6.2"],"_product_image_gallery":["42832,42833,42834,42835,42836"],"_edit_lock":["1753391049:18"],"_edit_last":["18"],"_advads_ad_settings":["a:1:{s:11:\"disable_ads\";i:0;}"],"site-sidebar-layout":["default"],"ast-site-content-layout":["default"],"site-content-style":["default"],"site-sidebar-style":["default"],"theme-transparent-header-meta":["default"],"stick-header-meta":["default"],"_yoast_wpseo_primary_product_cat":["6793"],"_yoast_wpseo_focuskw":["8KW Diesel Air Heater"],"_yoast_wpseo_metadesc":["Download the VEVOR 8KW Diesel Air Heater manual for easy setup, operation, and troubleshooting. Perfect for Boat, Bus, RV, and Trailer. Get expert guidance!"],"_yoast_wpseo_linkdex":["71"],"_yoast_wpseo_content_score":["30"],"_yoast_wpseo_focuskeywords":["[]"],"_yoast_wpseo_keywordsynonyms":["[\"\"]"],"_yoast_wpseo_estimated-reading-time-minutes":["31"],"_regular_price":["0.00"],"_price":["0.00"],"astra-migrate-meta-layouts":["set"],"_yoast_wpseo_primary_product_brand":[""],"_yoast_wpseo_title":["VEVOR 8KW Diesel Air Heater Manual, 12V 10L Tank"],"_uag_page_assets":["a:9:{s:3:\"css\";s:0:\"\";s:2:\"js\";s:0:\"\";s:18:\"current_block_list\";a:11:{i:0;s:11:\"core\/search\";i:1;s:10:\"core\/group\";i:2;s:12:\"core\/heading\";i:3;s:17:\"core\/latest-posts\";i:4;s:20:\"core\/latest-comments\";i:5;s:13:\"core\/archives\";i:6;s:15:\"core\/categories\";i:7;s:10:\"core\/image\";i:8;s:10:\"core\/cover\";i:9;s:14:\"core\/paragraph\";i:10;s:13:\"advads\/gblock\";}s:8:\"uag_flag\";b:0;s:11:\"uag_version\";s:10:\"1777421511\";s:6:\"gfonts\";a:0:{}s:10:\"gfonts_url\";s:0:\"\";s:12:\"gfonts_files\";a:0:{}s:14:\"uag_faq_layout\";b:0;}"]},"uagb_featured_image_src":{"full":["https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-heater-m100-1.2-1.jpg",1600,1600,false],"thumbnail":["https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-heater-m100-1.2-1-150x150.jpg",150,150,true],"medium":["https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-heater-m100-1.2-1-300x300.jpg",300,300,true],"medium_large":["https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-heater-m100-1.2-1-768x768.jpg",768,768,true],"large":["https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-heater-m100-1.2-1-1024x1024.jpg",1024,1024,true],"1536x1536":["https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-heater-m100-1.2-1-1536x1536.jpg",1536,1536,true],"2048x2048":["https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-heater-m100-1.2-1.jpg",1600,1600,false],"woocommerce_thumbnail":["https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-heater-m100-1.2-1-300x300.jpg",300,300,true],"woocommerce_single":["https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-heater-m100-1.2-1-600x600.jpg",600,600,true],"woocommerce_gallery_thumbnail":["https:\/\/i.vevor.net\/wp-content\/uploads\/2024\/12\/diesel-heater-m100-1.2-1-100x100.jpg",100,100,true]},"uagb_author_info":{"display_name":"Aurora","author_link":"https:\/\/www.vevor.com\/diy-ideas\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"Efficient Diesel Heater: Heater Power: 8KW; Rated Voltage: 12V; Heater Working Temp: -40\u2103~+20\u2103; Oil Pump Working Temp: -40\u2103~+20\u2103. On cold winter days, we have got you covered with this diesel air heater to warm your car and eliminate the windows' frost. With fast heating and low noise, the aluminum heater runs smoothly in any harsh&hellip;","_links":{"self":[{"href":"https:\/\/www.vevor.com\/diy-ideas\/wp-json\/wp\/v2\/product\/42831","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.vevor.com\/diy-ideas\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.vevor.com\/diy-ideas\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.vevor.com\/diy-ideas\/wp-json\/wp\/v2\/comments?post=42831"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.vevor.com\/diy-ideas\/wp-json\/wp\/v2\/media\/42830"}],"wp:attachment":[{"href":"https:\/\/www.vevor.com\/diy-ideas\/wp-json\/wp\/v2\/media?parent=42831"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.vevor.com\/diy-ideas\/wp-json\/wp\/v2\/product_brand?post=42831"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.vevor.com\/diy-ideas\/wp-json\/wp\/v2\/product_cat?post=42831"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.vevor.com\/diy-ideas\/wp-json\/wp\/v2\/product_tag?post=42831"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}