Homepage » Products » VEVOR Automotive Smoke Leak Detector Smoke Machine Tester EVAP Fuel Pipe System Manual

VEVOR Automotive Smoke Leak Detector Smoke Machine Tester EVAP Fuel Pipe System Manual

VEVOR Automotive Smoke Leak Detector Smoke Machine Tester EVAP Fuel Pipe System Manual

Find All Kinds of Detector: VEVOR’s smoke leak detector allows for quick and efficient detection of leaks in various pipe systems, including the intake system, exhaust system, EVAP system, fuel tank system, and car sealing test. Quickly position the leakage on any pipe system with VEVOR’s smoke leak detector.
Easy to Use: To use VEVOR’s smoke leak detector, first fill the detector with 10-20ml of test oil, using our special fume oil (included); you can also use mineral oil or baby oil (not included). Then, disconnect the pipe you want to test and connect the detector to a battery. The car pipes can be filled with smoke and after waiting for approximately 2 minutes, you can begin checking for system leakage fault points.
Convenient Mechanics Tool: Smoke output: 15-20L/min; Output pressure: 15PSI. The portable smoke tester has a built-in air pump with a pressure of 15psi. You do not need to connect an external pump. With a pressure gauge, you can observe the gauge to more accurately determine whether the car pipeline is leaking. And an adjustable flowmeter, so that you can easily adjust the size of smoke according to the needs of the work.
Dual Modes: Our smoke leak tester has a dual testing model, including air and smoke modes. Air Mode: There is flow-meter from 1 to 6 to adjust the smoke concentration grade, which precisely locates these small and hard to find leaks to avoid unforeseen accidents. Smoke Mode: The detector can generate smoke in 30 seconds, quickly help you detect if leak exist.
Safe for All Vehicles: The automotive smoke machine detector is suitable for all vehicle models, including cars, motorcycles, snowmobiles, ATVs, light trucks, and speedboats. You can use it to detect leaks in pipe systems on these vehicles.

Unlock the full potential of your VEVOR Automotive Smoke Leak Detector Smoke Machine Tester EVAP Fuel Pipe System with our comprehensive product manual. This detailed guide is designed to make your experience seamless, whether you’re troubleshooting, setting up, or optimizing your device.

The manual offers step-by-step instructions, clear illustrations, and expert tips to help you efficiently identify leaks in your vehicle’s fuel system.

By downloading this manual, you gain access to invaluable information that simplifies maintenance, enhances performance, and ensures the longevity of your smoke machine tester. Download now for a hassle-free, user-friendly guide that meets all your automotive diagnostic needs.

MODEL: SDT-205S

Warning

FCC INFORMATION

CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment!

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This product may cause harmful interference.
  2. This product must accept any interference received, including interference that may cause undesired operation.

WARNING: Changes or modifications to this product not expressly approved by the party responsible for compliance could void the user’s authority to operate the product.

Note: This product has been tested and found to comply with the limits for a Class B digital device under Part 15 of the FCC Rules. These limits are designed to protect reasonably against harmful interference in a residential installation.

This automotive smoke leak detector generates, uses, and can radiate radio frequency energy, and if not installed and used per the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. Suppose this product does cause harmful interference to radio or television reception, which can be determined by turning the product off and on. In that case, the user is encouraged to try to correct the interference by one or more of the following measures.

  • Reorient or relocate the receiving antenna.
  • Increase the distance between the product and the receiver.
  • Connect the product to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for assistance.

Product information and packing list

1   Power source: Vehicle DC12V battery

2   Vehicle battery smoke flow: 15~20 L/min

3   Flow control: Adjustable

4   Rated power: 100 W

5   Rated voltage: DC12V

6   Product  weight: 5.6 kg

7    Boundary dimension: 370*345*295 mm

8   Ressure control: Adjustable

9    Air source: Internal air source

Automotive Smoke Leak Detector Structure

Quick detection indicator: For non-smoke leakage detection, leakage in the pipe is quickly detected.

  • Smoke detecting indicator: To detect the leakage point quickly for smoke leakage detection.
  • Power indicator: This indicates the detector’s power status.Working indicator: The working indicator is on when the detector is in use.Working mode selection switch: This switches between quick detection mode and smoke detection mode.
  • Working switch: one pressing is on; one more pressing is off. A high-accuracy pressure gauge is used to display the working pressure during detection and to make judgments.
  • Air flow meter: This is used to adjust the air flow by the air flow to judge the severity of leakage.
  • Smoke outlet pile: The detector’s smoke outlet is connected to the detection port.
  • Power supply cable: Input DC12V, connected to vehicle battery.

Attention: For the first usage, oil filling 20- 30ml, please do not fill more than this amount.When the smoke is low, less than 20ml is needed for each refill. Please replace the internal oil regularly.

Note: During the refilling, please ensure the detector is powered off and cooled down, otherwise there is the risk of damaging it.

Operating Instruction

  • Place the detector on a flat surface, tighten the air cell adaptor clockwise, and insert the front end into the pile that needs to be detected.
  • Press the manual pump to inflate the air cell, seal the pile completely, and ensure no leakage. Insert the outlet of the smoking pipe into the air cell adaptor’s inlet, ensuring there is no leakage. Connect the detector to the vehicle DC12V battery, connect RED to “+”, black to“-”. When the power is connected correctly, the power indicator will be on.

Note: DO NOT CONNECT THE TERMINAL IN REVERSE

  • Select the working mode; the default is quick detection mode. If there is already a leakage, please select smoke mode directly.
  • Turn on the switch; the detector starts to work.
  • Adjust the air flow valve to control the air flow and fit the pressure capability of the pipe system.
  • If the quick detecting mode is chosen, after operating for about 2 min, the float of the air flow meter will gradually sink to ”0,” which means there is no leakage in the pipe. On the contrary, there is leakage in the pipe. (The above operating leading time refers to a small vehicle; it will be a longer lead time for a big vehicle. The lead time will be different according to the size of the vehicle.)
  • If the smoke mode is chosen, after operating for about 2 minutes, the pipe will be filled with smoke. (The above operating lead time refers to a small vehicle; it will be longer for a big vehicle. The lead time will be different depending on the size of the vehicle.)
  • Observe the floater’s status in the air flow meter; if it stands still at the bottom, there is no leakage in the pipe. On the contrary, if it goes up or jumps, there is leakage in the pipe.
  • The severity of the leakage can be judged by its position; the higher the floater, the heavier the leakage.
  • During the detection, please use light to illuminate if necessary. Where the smoke is observed is the leakage point.
  • When the detection is over, please properly store all the cables and pipes.
  • Note: Please try to avoid detecting areas that are sensitive to smoke.
  • During the EVAP system detection, please check the pressure in real time, and turn off the air flow control switch on time.

Each operation should not be more than 20 minutes, please wait for 15 minutes between two usages. The detector is equipped with a protective device; it will be powered off automatically when a specific limit is reached. In this case, please pause the next usage.

PLEASE DO NOT CONNECT THE POWER CABLE IN REVERSE. In this case, it will trigger the self-protecting function; the detector will not function. If the power cable is connected in the wrong way frequently, it will damage the detector or influence the device’s lifetime.

Daily maintenance and consumables

  1. In a high-temperature environment, the smoke oil will oxidize and deteriorate, influencing the lifetime of the smoke-generating element; it needs to be replaced regularly.
  2. When the detector is not used for over a week, it must be refilled with new oil. Please drain the used oil.
  3. When there are many water drops at the smoke outlet port, please replace the oil.
  4. It is recommended to use the specific smoke oil.
  5. Please use the oil bottle as an accessory for refilling.

Made in China.

VEVOR Automotive Smoke Machine Leak Detector, DC 12V EVAP Vacuum Diagnostic Tester with Built-in Air Pump, Dual-Mode Vacuum Pipeline Fuel Diagnostic Detector for Cars, Motorcycles, Trucks, Boats, ATVs
VEVOR Automotive Smoke Machine Leak Detector, DC 12V EVAP Vacuum Diagnostic Tester with Built-in Air Pump, Pressure Gauge & Flow Meter, 2-Mode Fuel Detector for Cars, Motorcycles, Trucks, Boats, ATVs
VEVOR Automotive Smoke Machine Leak Detector, DC 12V EVAP Vacuum Diagnostic Tester with Built-in Air Pump, Pressure Gauge & Flow Meter, Dual-Mode Detector for Cars, Motorcycles, Trucks, Boats, ATVs
VEVOR Automotive Smoke Machine Leak Detector, DC 12V EVAP Vacuum Diagnostic Tester with Built-in Air Pump & Pressure Gauge, 2-Mode Pipeline Fuel Detector for Cars, Motorcycles, Trucks, Boats, ATVs
VEVOR Automotive Smoke Machine Leak Detector, DC 12V EVAP Vacuum Diagnostic Tester with Built-in Air Pump & Pressure Gauge, Dual-Mode Pipeline Fuel Detector for Cars, Motorcycles, Trucks, Boats, ATVs
VEVOR Automotive Smoke Machine Leak Detector, DC 12V EVAP Vacuum Diagnostic Tester with Built-in Air Pump, Adjustable Pressure, Vacuum Pipeline Fuel Diagnostic Detector for Cars, Motorcycles, Boats

Recommended For Your Project

 

VEVOR Automotive Smoke Leak Detector Smoke Machine Tester EVAP Fuel Pipe System Manual

Reviews

There are no reviews yet.

Be the first to review “VEVOR Automotive Smoke Leak Detector Smoke Machine Tester EVAP Fuel Pipe System Manual”

Your email address will not be published. Required fields are marked *

Scroll to Top