Discover the ultimate resource for your VEVOR Temporary Power Outlet Panel with our comprehensive product manual. This manual is your go-to guide for setup, optimization, and troubleshooting, explicitly designed for the VEVOR Temporary Power Outlet Panel, 125/250V, RV Power Outlet Box. With a 20/30/50 Amp Receptacle Installed, including NEMA 14-50R, NEMA TT-30R, and 15A GFCI, this panel ensures reliable power for your RV camper, trailer, or motorhome. Our manual meets UL Standards, guaranteeing safety and reliability.
Inside this user-friendly manual, you’ll find step-by-step instructions, detailed diagrams, and essential tips to help you get the most out of your power outlet panel. Whether setting up for the first time or encountering an issue, our manual provides clear and concise guidance to keep your power supply running smoothly.
Download the VEVOR Temporary Power Outlet Panel manual today and experience unparalleled ease of use and peace of mind.
RV-30A/50A

Installation Instructions
Power Outlet Box
Sku#: DGNCRV203050AY3ZNV0
Model: RV-30A/50A
Desc: 50A 125/250V
NEMA: 14-50R/TT-30R/LD-3008B
WARNING!: ELECTRICAL SHOCK AND FIRE HAZARD!
The outlet is not to be connected to power before installation. Failure to comply with this instruction could
result in an electrical failure, fire, and electrocution.
IMPORTANT: A qualified electrician must install this power outlet box and related wiring in compliance with all applicable electrical codes. This outlet must be used in conjunction with a transfer switch when powering a structure. Not for indoor use. When using an engine-driven generator, locate it away from doors and windows to avoid the buildup of carbon monoxide from the engine exhaust in enclosed areas.
Installing the Power Outlet Box: Mount the power outlet box on the outside of the building in a convenient location, using thethree holes provided in the back of the cabinet, Using copper wire only and approved wiringmethods, run the wiring through one of the knockouts in the cabinet to a junction box located near the transfer switch, If using conduit, pull at least four colors.
WireGauge: 4AWG~8AWG.Strip the wire insulation 3/5″(15mm, FIG1) (do not tin conductors) and connect the wires in the power outlet box as follows: Make sure there is no wire insulation in any terminal, and the outlet terminal screws are tightened to 35 inch-pounds torque using an Electric flat Screwdriver.
Cable Color Scheme
Black/Red = Load (250 Vlot), the terminals marked “Black” and “Red”. (LINE)
White = W-Neutral Conductor connected to “White” marking terminal. (Neutral Bar)
Green=Green power inlet wire to green ground screw terminal on inside of cabinet. If required, green wire to
green ground screw terminal on inside of cabinet. (Ground Bar)

Temporary Power Outlet Panel Structure