Homepage » Products » VEVOR 3/4HP SUS304 Stainless Steel Shallow Well Jet Pump, 115 Volt, 18.5 GPM 131 FT Manual

VEVOR 3/4HP SUS304 Stainless Steel Shallow Well Jet Pump, 115 Volt, 18.5 GPM 131 FT Manual

High-Power, 131ft Head: Introducing our shallow well jet pump with a mighty 0.75 HP / 559.3W motor, engineered to boost water flow effortlessly. With a remarkable rated flow rate of 18.5 GPM, it reaches heights up to 131 FT / 40 m, exceeding expectations for household water needs. Say hello to superior performance and bid farewell to water worries!
Automatic Pressure Switch: Our shallow well jet pump starts and stops automatically when you turn on and off the faucet, saving you valuable time. Operating within the range of 20 – 40 PSI, it activates or deactivates in sync with your water valve, avoiding damage from clogged pipes or insufficient pressure. For precise monitoring of water pressure, consider purchasing a pressure gauge separately.
Easy Setup, Simple Use: Simply match the voltage, plug in the power, and install water pipes into the designated inlet and outlet ports. However, before use, fill the water filling nozzle with water until it flows out from the drain opening, then install the air vent plug. If infrequently used, remember to drain the water.
Built to Last: Crafted from 304 stainless steel, our shallow well jet water pump is wear-resistant and corrosion-resistant, making it ideal for outdoor use in courtyards and farms. With a rear heat dissipation port, it facilitates immediate cooling, while the built-in automatic thermal overload protector ensures uninterrupted operation for years to come.
Commercial & Household Use: This shallow well jet pump is incredibly versatile, perfect for supplying fresh water to large residences, farms, and cottages, while also providing solutions for garden irrigation, boosting water pressure for faucets, supplying water for car washing, and even facilitating high-rise water supply needs.

Unlock the full potential of your VEVOR 3/4HP SUS304 Stainless Steel Shallow Well Jet Pump with our comprehensive product manual. Designed for the 115 Volt, 18.5 GPM, 131 FT Maximum Head Irrigation Water Pump, this manual is your ultimate guide to setup, troubleshooting, and optimization.

Whether you’re using it for an agricultural garden irrigation system or a high-rise water supply shower booster, our detailed instructions will ensure you get the most out of your pump. With step-by-step guidance, clear diagrams, and helpful tips, this manual simplifies the installation process and helps you address any issues efficiently.

Download it now to ensure the seamless operation and long-lasting performance of your VEVOR water pump.

SPRINKLER PUMP MANUAL

SAFETY WARNINGS

WARNING: Read this material before using this shallow well jet pump. Failure to do so can result in serious injury. SAVE THIS MANUAL.

Before start-up, note the following:

The plug must have a supply voltage of AC115V 60 Hz.

CAUTION

This pump has been evaluated for use with water only.

WARNING

IMPORTANT! For your safety, before starting to run the pump, please have the following items checked by an expert:

  1. Risk of electric shock – This pump has a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain it is connected only to a properly grounded, grounding-type receptacle.
  2. Risk of electric shock – This pump has not been investigated for use in swimming pool areas.
  3. The electrical connections must be protected from moisture.
  4. If there is danger of flooding, the electrical connections must be taken to higher ground.
  5. Circulation of caustic fluids, as well as the circulation of abrasive materials, must be avoided at all costs.
  6. The pump must be protected from frost.
  7. The pump must be protected from running dry.
  8. Access by children should also be prevented with appropriate measures.
  9. The pump must be connected only to a GFCI-protected outlet to prevent death from electric shock.
  10. Do not use an extension cord with this item.
  11. People with pacemakers should consult their physician(s) before use. Electromagnetic fields close to a heart pacemaker could cause pacemaker interference or failure.
  12. The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur.
  13. The operator must understand that common sense and caution are factors that cannot be built into this product, but must be supplied by the operator.

Fluid Type

The Pump is designed for use with water with a maximum temperature of 95°F (35°C). Do not use the pump
for other fluids, especially not fuels, cleaning fluids, or other chemical products.

WELL JET PUMP SPECIFICATIONS

The pump must be installed in a stationary position with either:

  • A fixed pipeline or
  • A flexible hose pipe.

Please note!

Please do not install the pump by suspending it from being unsupported by its delivery pipe or power cord. The pump must be suspended from the handle or be placed on the bottom of the basin. To ensure the pump works properly, keep the bottom free from sludge and dirt.

If the water level sinks too low, any sludge in the basin will dry out and stop the pump from starting. To help ensure the pump will start as required, check the pump regularly with start-up tests.

Power Supply

  1. The pump is equipped with a shock-proof plug according to regulations. The pump is designed to be connected to 115 VAC, 60 Hz GFCI socket.
  2. Make sure that the socket is sufficiently secured and is in excellent condition.
  3. The pump will be on standby when the plug is inserted into the socket.
  4. WARNING: The pump must be connected only to a GFCI-protected outlet to prevent death from electric shock.

WARNING! TO PREVENT SERIOUS INJURY:

Do not use the pump if the power cord or plug is damaged. The power cord or plug may only be repaired by a certified electrician.

Areas of use

  1. This pump is designed to pump water only.
  2. This pump is designed for Irrigation systems, lawn sprinkling, and clear water transfer.
  3. This pump should NOT be used for continuous running or fountain/pond water features. Water with dirt and debris. Removing water fromswimmingpoolsorspas.Septic or sewage systems.
  4. This pump can also transfer water (e.g., household, farming, plumbing).

INSTALLATION INSTRUCTIONS

1. Position Pump on solid surface.

WARNING! TO PREVENT SERIOUS INJURY: This is NOT a submersible pump. Do not immerse in water.

2. Plug Power Cord into a GFCI-protected outlet.

3. The Pump uses 3/4″ NPT piping (sold separately)

Purchase the necessary length of pipe, including any needed fittings and bends.

Mount the Pump as close to the water source as possible and within the range of the rated Suction Lift. The connections must be airtight. Wrap all threaded connections with PTFE tape (sold separately).

4. Remove the Inlet and Outlet Covers from the Pump.

5. Attach the water source to the Inlet, using appropriate methods. The inlet hose or pipe must be collapsible to withstand the suction force properly.

6. Install a foot valve and filter (sold separately) at the bottom of the inlet.

7. Attach the outlet connection to the Outlet. A Y-fitting with dual valves (sold separately) helps prime the pump (see Figure B).

Note: A foot valve on the inlet connection is critical to help prevent the pump from losing prime. Note: Check that the water source and piping are clear of sand, dirt, and debris.

8. As shown above, connect a bucket full of at least 3 gallons of water to one side of the Y-fitting using a hose. (If available, a continuous water supply, such as a spigot, may be used instead.) The bucket must be positioned higher than the pump’s outlet.

9. Close the valve on the outlet side of the Y-fitting, and open the priming side.

10. Remove the Priming Plug and wait until water starts coming out of the Priming Plug. Replace the Priming Plug and tighten securely.

OPERATION

After reading these instructions, consider the following points before starting the pump:
1. Verify that the discharge pipe is connected correctly.

2. Verify that the electrical connection is AC115V, 60 Hz.

3. Verify that the electrical socket is GFCI protected and in good condition. Test the GFCI-protected outlet before use.

4. Verify that water and moisture cannot reach the power supply socket.

5. Verify that the pump is installed to prevent running dry.

6. To start the pump:

  • Open the valve on outlet side of the Y-fitting.
  • Make sure your hands are dry.
  • Plug in the pump.
  • Turn on the Power Switch (I).
  • Close the valve on the priming side of the Y-fitting.

NOTICE: Do not run the Pump Dry!

Turn off the Pump IMMEDIATELY if water stops coming out of the Outlet.

7. If you operate the Pump and no water comes out, shut the Pump off IMMEDIATELY. Check the pipes for air-tightness. Check also that the bottom of the Inlet pipe is underneath the water’s surface, and a foot valve is installed correctly.

8. After the pump runs correctly, The priming hose and bucket can be disconnected.

9. When finished using the pump, turn the Power Switch off (O), then unplug the Power Cord. Follow the procedures for Storage explained on the next page.

SHALLOW WELL JET PUMP MAINTENANCE

WARNING

TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:

Unplug the Pump from its electrical outlet before performing any inspection, maintenance, or cleaning procedures.

If the pump is moved during operation, flush it with clean water after every use.

QUARTERLY MAINTENANCE

The maintenance below must be performed at least once every 3 months under optimal conditions.

For frequent use or dirty areas, more frequent maintenance is required.

  1. Clean sludge and debris from the bottom of the basin.
  2. Clean sludge/debris from the inlet screen.
  3. Make sure the discharge pipe is free from leaks.
  4. Make sure the check valve is functioning correctly.
  5. Manually operate the flow switch to determine that the pump turns on/off as intended.

LONG-TERM STORAGE

  1. Drain Pump Body. Disconnect both suction and outlet lines, then tip the pump so that all water is drained from the pump cavity.
  2. If the Pump sits idle for 5 days or more, it should be unplugged and rotated with a screwdriver through the middle hole of the fan cover through several revolutions to prevent it from taking a permanent set.
  3. If you use the Pump only occasionally, replace the Inlet and Outlet covers to protect the unit when you are done pumping.

Troubleshooting the Shallow Well Jet Pump

JET PUMP PARTS LIST AND DIAGRAM

PLEASE READ THE FOLLOWING CAREFULLY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY.

NEITHER THE MANUFACTURER NOR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT.

THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER.

THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.

Shallow Well Jet Pump Parts List

Made In China.

VEVOR 1 HP Shallow Well Jet Pump, AC 115/230 Volt, 1400 GPH Dual Voltage Cast Iron Well Jet Pump, with 164 ft Max Head Lift, Automatic Pressure Switch, for Garden Irrigation Lawn Sprinkler System
VEVOR 1.5 HP Shallow Well Jet Pump, AC 115/230 Volt, 4250 GPH Dual Voltage Cast Iron Well Jet Pump, with 108 ft Max Head Lift, Easy Voltage Switching, for Garden Irrigation, Lawn Sprinkler System
VEVOR 2 HP Shallow Well Jet Pump, 230 Volt, 5200 GPH Cast Iron Well Jet Pump, with 112 ft Max Head Lift, Check Valve, Thermal Protection, Automatic On/Off, for Garden Irrigation Lawn Sprinkler System
VEVOR 1/2 HP Shallow Well Jet Pump, AC 115/230 Volt, 790 GPH Dual Voltage Cast Iron Well Jet Pump, with 147 ft Max Head Lift, Automatic Pressure Switch, for Garden Irrigation Lawn Sprinkler System
VEVOR 3/4HP SUS304 Stainless Steel Shallow Well Jet Pump, 115 Volt, 18.5 GPM 131 FT Maximum Head Irrigation Water Pump, for Agricultural Garden Irrigation System High-Rise Water Supply Shower Booster
VEVOR Shallow Well Pump, 1HP 115V, 1200 GPH 145 ft Head, Portable Stainless Steel Sprinkler Booster Jet Pumps with Automatic Controller for Garden Lawn Irrigation system, Water Transfer

Recommended For Your Project

VEVOR 3/4HP SUS304 Stainless Steel Shallow Well Jet Pump, 115 Volt, 18.5 GPM 131 FT Manual

Reviews

There are no reviews yet.

Be the first to review “VEVOR 3/4HP SUS304 Stainless Steel Shallow Well Jet Pump, 115 Volt, 18.5 GPM 131 FT Manual”

Your email address will not be published. Required fields are marked *

Scroll to Top