With a user-friendly layout and easy-to-follow sections, you’ll find all the information you need about the 0-120 min time setting, maintenance practices, and safety precautions. Perfect for homes, offices, cars, and pet areas, this manual ensures you get the most out of your VEVOR Ozone Generator, enhancing air quality and eliminating odors effectively.
VEVOR Ozone Generator User Manual
MODEL: SS-Y01

Important Safeguards
When using electrical appliances, basic safety precautions should be followed, including the following.
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE
WARNING: To reduce the risk of fire, electric shock, or injury:
- Do not leave the appliance when plugged in. Unplug from the outlet when not in use and before servicing.
- Do not use outdoors or on wet surfaces
- Do not allow it to be used as a toy. Children shall not play with the appliance. Children shall not make cleaning and user maintenance without supervision.
- This appliance is not intended for use by persons(including children) with reduced physical, sensory, or mental capabilities or a lack of experience and knowledge unless they have been given supervision or instruction concerning its use by a person responsible for their safety. Children should be supervised to ensure they do not play with the appliance.
- To protect against electrical hazards, do not put the ozone generator in water or other liquids
- Do not operate the ozone generator or any other electrical equipment with a damaged cord or plug or after the unit malfunctions or is dropped or is damaged in any manner. Return it to the nearest authorised service facility for examination, repair, or adjustment.
- Do not let the cord hang over the table’s edge or counter or touch hot surfaces.
- Put this instruction manual in a safe place. Do not discard.
- If the power cord is damaged, it must be replaced by the manufacturer, its service agent, or a similarly qualified person to avoid a hazard.
- Electric Shock Danger! Non-professional personnel are forbidden to repair the products; otherwise, they may result in electrical shock. When failures happen, they should be repaired by qualified maintenance personnel.
- Do not place the product directly on the fire or near the source of fire; otherwise, it will be damaged or even cause danger. Once part of the product is on fire, do not directly use water to extinguish the fire. Use a wet cloth to cover the fire site.
- When the plug is plugged into the socket, it must be plugged into the end; otherwise, poor contact will cause the components to overheat and burn.
- WARNING! Putting the main body of the machine and the power cord into any liquid is strictly prohibited. Unplug the machine from the outlet before any routine cleaning or maintenance.
- WARNING! Use in unoccupied spaces only
- WARNING! It is forbidden to use in flammable, explosive, humid, and other harsh environments.
- WARNING! It is forbidden to cover the air inlet and outlet. And the exhaust hole is strictly prohibited from blocking foreign objects
CAUTIONS
- The ozone generator is a high-voltage product, so it should be stored safely and in a solid state when not in use.
- When the ozone generator is working, please ensure that people, pets, and living things are in the room.
- Ozone has strong oxidising properties; we recommend that the device’s operating time does not exceed 2 hours each time.
- Ozone is extremely unstable, automatically decomposes into oxygen after one hour, with no pollution or residue.
- Ozone has a special smell. If you are sensitive to the smell of ozone, please stay away from the device.
- Non-professionals are not allowed to disassemble the device without authorisation. The power supply should be cut off if it is not used for long.
- The device must be powered off during maintenance, and the power must be cut off immediately when an abnormality is found.
SAVE THESE INSTRUCTIONS
Functional application:
Ozone ( 03 ) is an allotrope of oxygen ( O2 ) . It is gaseous at room temperature. When the concentration is low, it is colorless and has a grassy smell. The chemical properties of ozone are more active and have strong oxidising power.
When it encounters bacteria and harmful chemicals(such as formaldehyde, benzene, and ammonia ), it immediately produces an oxidation reaction, thereby achieving the functions of sterilisation and disinfection, deodorisation, and decomposition of harmful gases. Ozone is extremely unstable and will be reduced to O2 within a few hours, so no pollution or residue exists. It is the only substance recognised in the world that can directly sterilize food and beverages so far!
1 . The strong oxidizing properties of ozone can remove toxic substances released by decoration, synthetic boards, and paints, kill bacteria and viruses in the air, kill microorganisms that breed in carpets, eliminate cold germs, prevent the occurrence of flu, and increase indoor oxygen content.
2 . Ozone has excellent odor removal performance. The main odour components are amine R3N, hydrogen sulfide H2S, methyl mercaptan CH2SH, etc. The strong oxidizing performance of ozone can quickly decompose odor and other organic or inorganic substances
Ozone Generator Parameter Table

How to Use the Ozone Generator
1 . Insert the power cord plug into the disinfection machine’s socket, and connect the other end to the 120V 60Hz AC power supply.

2 . Turn on the steriliser’s power switch. The red light will be on, which means the machine is powered on.

3. Set working status
Normally open: Turn the timing knob counterclockwise. When the pointer of the knob is aligned with the ” HOLD ” gear, the device will start, and there is no timing function.

Off: Turn the knob and the pointer is aligned with the ” OFF” gear, the equipment stops working
Timing: Turn the knob clockwise, the pointer is aligned the dial, and the device is in timing working mode
The number pointed by the pointer is the set working time. The equipment stops working at the end of working hours. (For example, the pointer in the figure below is aligned with 40, that is, the device will shut down after 40 minutes of operation)

Note: Regardless of whether it is in the normally open or timing mode, the cumulative working time for a single operation should not exceed 1 hour.
Precautions
- It is forbidden to use in flammable, explosive, humid and other harsh environments
- It is forbidden to cover the inlet and outlet.
- People should be evacuated temporarily when the equipment is working.
- The power must be cut off during equipment maintenance.
- Non-professionals are not allowed to disassemble the equipment without authorisation
- Cut off the power supply if it is not used for a long time,
- The cumulative working time at one time does not exceed1hour, and the equipment can be restarted after cooling down.
- Regularly check whether the equipment is working normally, and immediately cut off the power supply if any abnormality is found.